5.5

Installation Steps

WARNING
The Actuator is intended for installation on your custom-made mounting support.
For the standard 2000X Micro Actuator, it is located in place with a mounting pin and
secured using two metric bolts.
1. Lift the Actuator from the box. Carefully lay the assembly on its side
2. Install the mechanical stop. See section
3. Use of guide pins is suggested. They are not provided with the Actuator. If you require guide
pins, use solid metal dowel pins, 8 mm diameter, which must not extend into the actuator more
than 0.40 inch (10 mm) into your Actuator
CAUTION
52
General Warning
This product is heavy and can cause a pinching or crushing injury
during installation or adjustment. Keep clear of moving parts.
5.5.1 Installing the Mechanical Stop
General Warning
The Actuator supports bolts for the 2000X Micro Actuator are metric,
M8 x 1.25 thread pitch, 22 mm long. The support pin and mounting
bolts must not extend more than 0.62 in (15 mm) into the Actuator,
otherwise, binding or damage to the carriage may occur.
100-412-182 REV. 06