Section 5: Mechanical Stroke Adjustment - Emerson EL-O-Matic F Series Installation, Operation And Maintenance Manual

Rack and pinion pneumatic actuators
Hide thumbs Also See for EL-O-Matic F Series:
Table of Contents

Advertisement

Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 6

Section 5: Mechanical Stroke Adjustment

This section explains:
EL-O-Matic F actuator sizes 25 to 4000 have two stroke adjustment stops for adjusting
accurately the stroke of the actuator/valve assembly in open and closed position.
The smallest actuator, size F12, does not have limit stops.
The factory setting of the stroke is 90°. Most quarter-turn valve applications will not require
readjustment of these settings.
If required the stroke can be adjusted by means of two-stroke adjustment bolts.
Figure 13
80°
95°
Installation
What mechanical stroke adjustment is.
What the factory settings are.
How to adjust the travel stops.
Factory Setting
Size 25 - 600
10°
-5°
90°
80°
93°
Size 950 - 4000
10°
-3°
90°
Section 4: Installation
September 2015
Limit Stop 2
Limit Stop 1
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents