Figure 5.14 Installing The 40 Khz Stack In The 2000X Micro Actuator - Emerson Branson 2000X Original Instructions Manual

Micro actuator
Table of Contents

Advertisement

5.7.3
Installing the Stack in the Actuator
The ultrasonic stack must first be assembled. To install the stack:
1. Make sure that the system power is turned off by disconnecting the power plug
2. Loosen the four carriage door screws

Figure 5.14 Installing the 40 kHz Stack in the 2000X Micro Actuator

Washer Orientation
for Solid-Mount Booster
3. Pull the door straight off and set it aside
4. Take the assembled stack and align the ring nut on the booster just above the support washer in
the carriage. Firmly push the stack assembly into place, with the acorn nut on top of the
converter making contact with the contactor in the tip of the carriage
NOTICE
5. Reinstall the door assembly, and start the four door screws
6. Align the horn by rotating it, if necessary. Torque the carriage door to 20 in-lbs to secure the
stack
64
Washer Orientation
for O-Ring Booster
Stack Assembly
Carriage
Support
Washer
Screw
Main Support
Assembly
Depending on your booster type, the step washers on the bottom of
the carriage may need to be reversed. See
40 kHz Stack in the 2000X Micro Actuator
the step washer.
Hex Screw
Carriage Door
Contact
Terminal
Stack Assembly
Carriage
Figure 5.14 Installing the
for proper orientation of
100-412-182 REV. 06