Signals - RME Audio M-32 AD Pro II-D User Manual

32-channel 192 khz a/d converter with madi & dante
Hide thumbs Also See for M-32 AD Pro II-D:
Table of Contents

Advertisement

2. Change OVR Hold to either:
◦ 5s to notify for five seconds
◦ On to notify until manually reset
◦ Off to deactivate over notifications.
To reset infinite full scale notifications:
1. Open the visual feedback tab in the STATE section.
2. Activate Reset.
The remote shows an over notification above the level meter, both in miniature port level meters and the
larger level meters when a port is open.
To switch persistant over notifications on or off:
1. Locate the Visual Settings Tab.
2. Change Peak + OVR Hold to either
◦ 5s to notify for five seconds
◦ On to notify until manually reset
◦ Off to deactivate over notifications
To reset over notifications:
1. Within the Visual Settings Tab, use the ⟲ reset button.
8.4.4. Metering of Digital Signals
The incoming and outgoing digital signals can be visually inspected to ensure that signals are properly
received and routed. All levelmeters adhere to IEC 60268-18 scaling and feature RMS levels with a
separate peak indicator. Peak and over hold times can be configured in Section 8.4.3, "Persistent
Clipping Notifications and Peak Hold".
To show the digital level meters on the device display:
1. Open the input section (see: Section 2.2, "Use of the Display and Encoder").
On the web remote, each input and output port has integrated level meters.
30 | 8.4. Front Panel Illumination
RME M-32 AD Pro II-D User's Guide