2. Use the corresponding toggle switches on the web remote to switch off device lighting.
8.4.2. Changing the Meters to Peak or RMS Mode
Depending on the application, instantaneous peak level metering or a slower, averaged RMS metering
may be preferred.
To change the metering mode on the device:
1. Open the visual feedback tab in the STATE section.
2. Push the encoder on the current "Metering:" value to activate selection.
3. Change the value to "Peak" or "RMS".
To change the metering mode on the web remote:
1. Connect to the device remotely (see: Section 8.5.1, "Finding the Device on a Network").
2. Locate the visual feedback tab in the STATE section.
3. Push the Peak or RMS button in the global metering settings.
This is a global setting which affects both the front panel level meters and the remote
control interface.
8.4.3. Persistent Clipping Notifications and Peak Hold
The maximum level of signals can be saved and shown on the front panel and web remote. Clipping is
detected when three consecutive samples reach digital full scale (0 dBFS). The duration of how long the
maximum level or clipping is shown can be manually changed to either five seconds or until they are
manually reset.
This is a global setting which affects both the remote control and the device.
To switch over notifications on or off:
1. Open the visual feedback tab in the STATE section
RME M-32 AD Pro II-D User's Guide
State of Visual Feedback
Front Panel Dark Mode
Global Metering Options
Peak/Over Hold Reset
On the device, an over notification is signaled as a fast flashing (red) of the
label backlight.
8.4. Front Panel Illumination | 29