General
When handling loads with a working load limit (WLL) of 150 kg - 200 kg, the
radius of the mast must be limited to 3000 mm.
Otherwise there is a risk of the appliance tipping over when lifting loads!
In addition, the chassis must be
loaded with sufficient
counterweights (e.g. with 400x300
mm stone slabs) on both sides of
the chassis (on site).
Otherwise there is a risk of the
appliance tipping over when lifting
loads!
3.4

Definition of load-bearing capacity

 Best.-Nr.: 52000025-150 = Maximum load capacity (WLL) 150 kg * (with lifting unit HE-150, this may be
operated with a corresponding suction plate with a minimum load capacity (WLL) of 150 kg or higher)
Best.-Nr.: 52000025-200 = Maximum load capacity (WLL) 200 kg * (with HE-200 lifting unit, this may be
operated with a corresponding suction plate with a minimum load capacity (WLL) of 200 kg or higher)
*
with negative pressure – 420 mbar
In general, the use of all Probst lifting units is permitted up to a load capacity (WLL) of 150 kg with
unrestricted outreach. For load capacities (WLL) higher than 150 - 200 kg, the throat depth is restricted (to
3000 mm). The load capacity (WLL) of the suction plate must always be equal to or higher than that of the
lifting unit!
52000029 / 52000029-150 / 52000029-200