Maintenance and care
7.2
Maintenance schedule
Check safety devices:
- Pressure gauge OK?
Check filter?
Is the electrical installation still OK? Cable glands tight?
Check battery condition
Drain condensation water
Are the vacuum hoses in good condition (not brittle, not kinked
kinked, no chafe marks and therefore leak-proof)?
Are all connections tight (hose clamps etc.)?
Are the operating instructions still available and known to the
workers?
Check load-bearing parts (e.g. suspension) for deformation, wear
or other damage.
Clean/check suction plates, no cracks, sealing lip homogeneous
etc.? Replace if necessary
Has the UVV inspection sticker been renewed?
General condition of the device
Leak test
Blow out the filter element with compressed air. Do not
knock out the filter element!
Replace if heavily soiled
52000029 / 52000029-150 / 52000029-200
Interval
daily
weekly
X
X
X
X
X
X
33 / 37
monthly 1/2-
Annual
yearly
audit
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
GB