Adjust Max. Output Current - Ford PRO FPC-AC0080ZC-U Series Installation Manual

Electric vehicle charging station
Table of Contents

Advertisement

Installation Manual
CAUTION RISK OF DAMAGE TO THE EQUIPMENT
See Section 4.2. Adjust Max. Output Current for details on charger derate settings.
Step 11.
Lock the conduit on the enclosure. Refer to the following torque.
Conduit
1 "
Step 12.
Reassemble interior install cover and front cover then fasten M4 screw.
Screw
M4

4.2. Adjust Max. Output Current

Step 13.
Configure the rotary switch to set the Max. output current.
If the charger is installed on a circuit breaker smaller than 100A, the rotary switch
should be adjusted to limit charger output to less than or equal to 80% of the
circuit breakers rating. (Eg: For a 60A circuit breaker, the charger output limit
should be adjusted to no more than 48A.) If needed, Amperage Reduction Labels
are available to place on charger and circuit breaker.
WARNING RISK OF ELECTRIC SHOCK
If this unit is installed outdoors, the outlet must be rated for outdoor in-
stallation. The outlet must be installed properly to maintain the proper
NEMA rating of the enclosure.
Power must remain off before setting or configuring the rotary switch.
80A Charging Station Series 2
Torque
35 kgf·cm
Torque
15 kgf.cm
25
30.36 lbf·in
13 lbf·in

Advertisement