5. Extended Coil Capability

The Extended Coil manifolds must be connected to a 580 Electronics Node to operate. Not all 580
supported protocols will support the Extended Coil Manifolds. Below is a list of the hardware and
minimum firmware levels that support the Extended Coil Manifolds.
Communication Module
Communication Module
Module firmware revision levels can be confirmed in the integrated graphic display. See pg. 6-38
for more information.
5.1

Extended Coil Configuration

The Extended Coil Manifold can be configured to control 3 additional extended coil valve driver
assemblies; unless already configured from the factory. Modify the configuration with the graphic
display interface as shown on page 6-30.
Number of Extended
Valve Series
Coil Valve Drivers
501
502/503
Distributed by Valin Corporation | www.valin.com | (800) 774-5630 | customerservice@valin.com
580 EtherCAT
Extended Solenoid Coil Capability requirements:
Module
Part Number
P580AEEC1010A00
P580AEEC1010DRM
Total number of coils
0
3-32
1
33-64
2
65-96
3
97-128
0
1-32
1
33-48
2
49-64
3
65-80
TD580ECTM1-3EN
Subject to change without notice
www.emerson.com
TM
Technical Manual
Firmware
Rev 1.1 Build 42963
Rev 1.1 Build 42963
Configuration
Selection
32 coils
64 coils
96 coils
128 coils
32 coils
64 coils
64 coils
96 coils
09/2021
Allocated number of I/O
Bytes designated for
valves
4
8
12
16
4
8
8
12
5-22