500 Series Extended Coil Capability

The Extended Coil manifolds must be connected to a G3 Electronics Node to operate. Not all G3 supported
protocols will support the Extended Coil Manifolds. Below is a list of the hardware and minimum firmware
levels that support the Extended Coil Manifolds.
Extended Solenoid Coil Capability requirements:
Module
Communication Module
Valve Driver Module
Module firmware revision levels can be confirmed in the integrated graphic display and the built-in web
browser. See pg. 5-48 for more information.

Extended Coil Configuration

The Extended Coil Manifold can be configured to control 3 additional extended coil valve driver assemblies;
unless already configured from the factory. Modify the configuration with either the graphic display
interface as shown on page 5-34 or using the integrated web server configuration page shown on page 9-
85.
Number of Extended
Valve Series
Coil Valve Drivers
501
502/503
G3 Series EtherCAT
Part Number
240-310
P599AE508827001
Total number of coils
0
3-32
1
33-64
2
65-96
3
97-128
0
1-32
1
33-48
2
49-64
3
65-80
TDG3ECM1-5EN
Subject to change without notice
www.asco.com/g3
Technical Manual
TM
Firmware
Rev 1.01 Build 42509
Rev 4.019
Configuration
Selection
32 coils
64 coils
96 coils
128 coils
32 coils
64 coils
64 coils
96 coils
07/2020
Allocated number of I/O
Bytes designated for
valves
4
8
12
16
4
8
8
12
9-85