Daikin ERLA14D V3 Series Installer's Reference Manual page 123

Hide thumbs Also See for ERLA14D V3 Series:
Table of Contents

Advertisement

ERLA11~16D + EBSH/X(B)11+16P30+50D
Daikin Altherma 3 R ECH₂O
4P663482-1C – 2023.05
Method 2: Using round crimp-style terminal
1 Strip insulation from wires and slightly twist the end of each wire.
2 Install a round crimp-style terminal on the end of the wire. Place the round
crimp-style terminal on the wire up to the covered part and fasten the
terminal with the appropriate tool.
Use the following methods for installing wires:
Wire type
Single-core wire
Or
Stranded conductor wire
twisted to "solid-like"
connection
Stranded conductor wire
with round crimp-style
terminal
Tightening torques
Outdoor unit:
Item
M4 (X1M)
M4 (earth)
M5 (X1M)
Installation method
c b
A
c
a
a Curled wire (single-core or twisted stranded
conductor wire)
b Screw
c Flat washer
c b
B
B
a
a Terminal
b Screw
c Flat washer
Allowed
NOT allowed
Tightening torque (N•m)
9
Electrical installation
|
AA´
a
a
b
c
1.2~1.8
1.2~1.4
2.0~3.0
Installer reference guide