Chapter 3 Modbus® Register Map - Banner S15L Pro Instruction Manual

In-line indicator with modbus
Table of Contents

Advertisement

 
S15L Pro In-Line Indicator With ModBus® Instruction Manual 
Chapter Contents
 
Chapter 3
Holding Registers for Device Information
Address
without Offset
1000
1001
1002
1003-1018
1019
1020
1021
1022-1037
1038-1053
Holding Registers to Configure Operation Mode
Address
without Offset
 3200
Holding Registers to Configure Normal Mode
Address
without Offset
3300
3301
3302
3303
3304
3305
3306
October 10, 2023
ModBus® Register Map
Address with
Description
Offset
1001
Low word model number
1002
High word model number
1003
Model version (BCD)
1004-1019
Model name, string
1020
Low word configuration number
1021
High word configuration number
1022
Configuration version (BCD)
1023-1038
Serial number/date code, string
1039-1054
Serial number, string
Address with
Description
Offset
3201 
Operation Mode
Address with
Description
Offset
3301
Animation
3302
Reserved
3303
Pulse Pattern
3304
Speed
3305
Reserved
3306
Reserved
3307
Reserved
© Banner Engineering Corp. All rights reserved.
Holding Register
Representation
Example: 0x0002A734 (hex)
= 173876 (dec)
High word = 0x0002
Low word = 0xA734
Example: 0x00016D43 (hex)
= 93507 (dec)
High word = 0x0002
Low word = 0xA734
Holding Register
Representation
0 = Normal Mode
1 = Demo Mode
Holding Register
Representation
0 = Off
1 = Steady
2 = Flash
3 = Two Color Flash
4 = Reserved
5 = Reserved
6 = Reserved
7 = Intensity Sweep
8 = Two Color Sweep
 0
0 = Normal
1 = Strobe
2 = Three Pulse
3 = SOS
4 = Random
0 = Slow
1 = Medium
2 = Fast
3 = Custom Flash Rate
 0
 0
 0
Continued on page 8
Default Value
Saved
Access
Yes
RO
See Device
Yes
RO
See Device
Yes
RO
S15L Pro
Indicator with
Yes
RO
ModBus
Yes
RO
See Device
Yes
RO
See Device
Yes
RO
See Device
Yes
RO
See Device
Yes
RO
Default Value
Saved
Access
0
No
RW
Default Value
Saved
Access
0
No
RW
0
No
RW
0
No
RW
0
No
RW
0
No
RW
0
No
RW
 
0
No
RW
7

Advertisement

Table of Contents
loading

Table of Contents