Banner SureCross Series Manual

Banner SureCross Series Manual

Advertisement

Quick Links

SureCross Temperature Probe with DX80 Node
Configurable temperature Node with thermocouple inputs and a battery integrated into the housing, mounted on a probe
For additional information, the most recent version of all documentation, and a complete list of accessories, refer to Banner Engineering's
website, www.bannerengineering.com/surecross.
Models
Description
BWA-TPROBE-001
Wireless DX80 Node and temperature
probe
BWA-TPROBE-002
DX80N9C-16999
DX80 Node (no probe assembly)
DX80N2C-16997
These Nodes are powered by an internal battery. All batteries must be ordered separately.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does NOT include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
The SureCross® DX80 Wireless Network
The SureCross® DX80 wireless I/O network provides reliable monitoring without the burden of wiring or conduit installation. The Sure-
Cross wireless network can operate independently or in conjunction with a host system, PLC, and/or PC software.
Each wireless network system consists of one Gateway and one or more Nodes. Devices ship with factory defined inputs and outputs
that may be all discrete, all analog, or a mix of discrete and analog I/O.
P/N 156525 rev. -
The SureCross® wireless system is a radio frequency network with integrated I/O that
can operate in most environments and eliminate the need for wiring runs. Wireless net-
works are formed around a Gateway, which acts as the wireless network master device,
and one or more Nodes.
This temperature probe is designed for measuring the temperature at three different
depths of a compost pile. A DX80 Node with a battery integrated into the housing trans-
mits the temperature readings to a Gateway.
• Wireless industrial I/O device with three thermocouple inputs
• FlexPower® technology driven by one lithium primary battery integrated into the
housing
• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multi-
ple Access (TDMA) control architecture ensure reliable data delivery within the unli-
censed Industrial, Scientific, and Medical (ISM) band
• Transceivers provide bidirectional communication between the Gateway and Node,
including fully acknowledged data transmission
• Internal antenna
Frequency
900 MHz ISM Band
2.4 GHz ISM Band
900 MHz ISM Band
2.4 GHz ISM Band
3/15/2013
I/O
Inputs: Three thermocouple
0 156525
6

Advertisement

Table of Contents
loading

Summary of Contents for Banner SureCross Series

  • Page 1 • Transceivers provide bidirectional communication between the Gateway and Node, including fully acknowledged data transmission • Internal antenna For additional information, the most recent version of all documentation, and a complete list of accessories, refer to Banner Engineering's website, www.bannerengineering.com/surecross. Models...
  • Page 2: Host Systems

    SureCross Temperature Probe with DX80 Node Node FlexPower Node and Battery Supply Module Gateway Node The SureCross® DX80 network is a deterministic system—the network identifies when the radio signal is lost and drives relevant outputs to user-defined conditions. Once the radio signal is reacquired, the network returns to normal operation. SureCross®...
  • Page 3: Configuring The Dip Switches

    For additional information, including installation and setup, weatherproofing, device menu maps, troubleshooting, and a list of accesso- ries, refer to one of the following product manuals. • SureCross Quick Start Guide: Banner part number 128185 • SureCross Wireless I/O Network Manual: 132607 •...
  • Page 4 SureCross Temperature Probe with DX80 Node Switches Device Settings Thermocouple, N-Type Thermocouple, P-Type Thermocouple, R-Type Thermocouple, S-Type Thermocouple, T-Type Thermocouple, U-Type * Default configuration. Address Mode The SureCross wireless devices may use one of two types of addressing modes: rotary dial addressing or extended addressing. In rotary dial address mode, the left rotary dial establishes the network ID and the right rotary dial sets the device ID.
  • Page 5: Modbus Register Table

    SureCross Temperature Probe with DX80 Node Terminal Block (Mini Board) 10-30. Power, 10 to 30V dc power connection. (For internal battery mod- els, do not use this connection.) 10-30 Ax+ and Ax-. Analog IN x. Analog inputs for devices requiring more than one connection, such as thermocouples or RTDs.
  • Page 6: Specifications

    SureCross Temperature Probe with DX80 Node Modbus Holding Register I/O Type Units I/O Range Holding Register Terminal Value Block La- bels Gateway Any Node Min. Max. Val- Min. Max. Value (Dec.) (Dec.) 4 + (Node# × 16) Thermocouple IN 2 °F/°C -1638.3 +1638.4 65535 A2+/A2-...
  • Page 7 Vibration: 0.5 mm p-p, 10 to 60 Hz Refer to the SureCross® DX80 Wireless I/O Network product manual, Banner p/n 132607, for installation and waterproofing instructions. Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
  • Page 8: Banner Engineering Corp Limited Warranty

    Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.

This manual is also suitable for:

Bwa-tprobe-001Bwa-tprobe-002Dx80n2c-16997Dx80n9c-16999

Table of Contents