(print, photocopy, microfilm or in any other process) without the express permission. We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in the handbook and assumes no responsibility for damages that occur...
Page 3
1 CAN 1 USB Host The S-DIAS PS 101 power supply module is a supply unit for a CPU component and the S-DIAS IO modules. The module also has a CAN and USB host interface, which only function when used with a CPU module such as the CP 111.
PS 101 S-DIAS POWER SUPPLY MODULE Contents Introduction ................5 Target Group/Purpose of this Operating Manual ...... 5 Important Reference Documentation ......... 5 Contents of Delivery ..............5 Basic Safety Directives ............6 Symbols Used ................6 Disclaimer ..................8 General Safety Directives ............
Page 5
S-DIAS POWER SUPPLY MODULE PS 101 Mechanical Dimensions ............17 Connector Layout ..............18 Status LEDs ................. 18 Connector ..................19 Applicable Connectors ............... 20 Label Field ................... 21 CAN Bus Setup ..............22 CAN Bus Station Number ............22 Number of CAN Bus Participants ..........
General knowledge of automation technology is required. Further help and training information, as well as the appropriate accessories can be found on our website www.sigmatek-automation.com. Our support team is happily available to answer your questions. Please see our website for our hotline number and business hours.
PS 101 S-DIAS POWER SUPPLY MODULE Basic Safety Directives Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes: DANGER Danger indicates that death or serious injury will occur, if the specified measures are not taken.
Page 9
S-DIAS POWER SUPPLY MODULE PS 101 INFORMATION Information Provides important information on the product, handling or relevant sections of the documentation, which require attention. 26.07.2023 Page 7...
It does not guarantee properties under the warranty. Please thoroughly read the corresponding documents and this operating manual before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through, non-compliance with these instructions or applicable regulations.
Regarding the requirements for Safety and health connected to the use of machines, the manufacturer must perform a risk assessment in accordance with machine directives 2006/42/EG before introducing a machine to the market. Operate the unit with devices and accessories approved by SIGMATEK only. 26.07.2023 Page 9...
PS 101 S-DIAS POWER SUPPLY MODULE CAUTION Handle the device with care and do not drop or let fall. Prevent foreign bodies and fluids from entering the device. The device must not be opened! Manipulez l’appareil avec précaution et ne le laissez pas tomber. Empêchez les corps étrangers et les liquides de pénétrer dans l’appareil.
• 2011/65/EU “Restricted use of certain hazardous substances in electrical and electronic equipment” (RoHS Directive) The EU Conformity Declarations are provided on the SIGMATEK website. See Products/Downloads or use the search function and the keyword “EU Declaration of Conformity”. 26.07.2023...
S-DIAS POWER SUPPLY MODULE PS 101 Technical Data Performance Data Interfaces 1x USB host 2.0 (high speed 480 Mbit/s) 1x CAN Status display Status LEDs The CAN and USB interfaces only function when used with a CPU module such a CP 111. Electrical Requirements 5.2.1 Module Supply (Input)
Page 16
PS 101 S-DIAS POWER SUPPLY MODULE Current consumption on the maximum 1.6 A S-DIAS bus (+24 V supply) the current consumption is dependent on the connected loads Page 14 26.07.2023...
PS 101 S-DIAS POWER SUPPLY MODULE Miscellaneous Article number 20-003-101 Standard UL 508 (E247993) Approbations UL, cUL, CE, UKCA Environmental Conditions Storage temperature -20 ... +85 °C Environmental temperature 0 ... +55 °C Humidity 0-95 %, non-condensing Installation altitude above sea 0-2000 m without derating level >...
PS 101 S-DIAS POWER SUPPLY MODULE Connector Layout INFORMATION The GND supply (X4: Pin 2 and Pin 3) is internally bridged. Only one GND pin (pin 2 or pin 3) is required to power the module. The bridged connections may be used for further looping of the GND supply. However, it must be taken into account that a total current of 6 A per connection is not exceeded by the forward looping! Status LEDs...
S-DIAS POWER SUPPLY MODULE PS 101 Connector X1: USB Host 2.0 (Type A) Function +5 V INFORMATION It should be noted that many of the USB devices on the market do not comply with USB specifications; this can lead to device malfunctions. It is also possible that these devices will not be detected at the USB port or function correctly.
PS 101 S-DIAS POWER SUPPLY MODULE Applicable Connectors X1: USB 2.0 Type A (not included in delivery) X2 and X3: Connectors with spring terminals (included in delivery) The spring terminals are suitable connecting ultrasonically compacted (ultrasonically welded) strands. Connections: Stripping length/Sleeve length: 10 mm Plug-in direction: parallel to conductor axis or to PCB...
S-DIAS POWER SUPPLY MODULE PS 101 Label Field Manufacturer Weidmüller Type MF 10/5 CABUR MC NE WS Weidmüller article number 1854510000 Compatible printer Weidmüller Type Printjet Advanced 230V Weidmüller article number 1324380000 26.07.2023 Page 21...
PS 101 S-DIAS POWER SUPPLY MODULE CAN Bus Setup This section explains how to correctly configure the CAN bus. The following parameters must first be set: Station number and data transfer rate. CAN Bus Station Number Each CAN bus station is assigned its own station number. With this station number, data can be exchanged with other stations connected to the bus.
S-DIAS POWER SUPPLY MODULE PS 101 CAN Bus Termination In a CAN bus system, both end modules must be terminated. This is necessary to avoid transmission errors caused by reflections in the line. If the PS 101 supply module with a processor module like the CP 111 is one of the end modules, it can be terminated by placing a 120 ...
PS 101 S-DIAS POWER SUPPLY MODULE Buffer Battery The exchangeable buffer battery ensures that programs and data in the expanded memory (SRAM) as well the clock time (RTC) of the CPU module (e.g. CP 111) are preserved in the absence of a supply voltage. A lithium battery is installed at the manufacturer. The battery has enough capacity to preserve data in the absence of a supply voltage for up to 3 years.
S-DIAS POWER SUPPLY MODULE PS 101 10 Wiring Guidelines The input filters, which suppress noise signals, allow operation in harsh environmental conditions. A careful wiring method is also recommended to ensure error-free function. The following guidelines should be observed: • Avoid parallel connections between input lines and load-bearing circuits.
PS 101 S-DIAS POWER SUPPLY MODULE 11 Assembly/Installation 11.1 Check Contents of Delivery Ensure that the contents of the delivery are complete and intact. See chapter 1.3 Contents of Delivery. INFORMATION On receipt and before initial use, check the device for damage. If the device is damaged, contact our customer service and do not install the device in your system.
S-DIAS POWER SUPPLY MODULE PS 101 11.2 Mounting The S-DIAS modules are designed for installation into the control cabinet. To mount the modules a DIN-rail is required. The DIN rail must establish a conductive connection with the back wall of the control cabinet. The individual S-DIAS modules are mounted on the DIN rail as a block and secured with latches.
Page 30
PS 101 S-DIAS POWER SUPPLY MODULE Recommended minimum distances of the S-DIAS modules to the surrounding components or control cabinet wall: a, b, c … distances in mm (inches) Page 28 26.07.2023...
S-DIAS POWER SUPPLY MODULE PS 101 12 Transport/Storage INFORMATION This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! Temperature and humidity fluctuations may occur during transport.
PS 101 S-DIAS POWER SUPPLY MODULE 14 Maintenance INFORMATION During maintenance as well as servicing, observe the safety instructions from chapter 2 Basic Safety Directives. 14.1 Service This product was constructed for low-maintenance operation. 14.2 Repair INFORMATION In the event of a defect/repair, send the device with a detailed error description to the address listed at the beginning of this document.
Page 33
S-DIAS POWER SUPPLY MODULE PS 101 Documentation Changes Change date Affected Chapter Note page(s) 11.02.2014 3 Connector Layout Changed image 01.04.2014 4.3 Can Bus Termination 150R to 120R changed 7 Mounting Text updated 16.04.2014 4.1 CAN Bus Station number Text updated 4.2 CAN Bus Participants Text updated 18.07.2014...
Need help?
Do you have a question about the S-DIAS PS 101 and is the answer not in the manual?
Questions and answers