Connection to window contact

The window contact connection
is live.
Danger of electric shock.
Disconnect the hob from the mains
electricity supply before connecting
the switching system.
The connection cable for the switch-
ing system must only be connected
by a suitably qualified electrician.
The connection cable for the switch-
ing system must comply with type
H03VV-F 2 x 0.75 mm
exceed 2.0 m in length.
The switching system must be
equipped with a potential-free con-
tact suitable for 230 V, 1 A. The va-
pour extraction is switched off when
the switch is open.
Only use DIBt-approved and tested
radio switching systems (e.g. window
contact switches, pressure switches)
and have them approved by author-
ised specialists (e.g. building regula-
tions inspector).
You will need the appropriate ex-
ternal switching system documents
to safely connect and operate the
switch.
2
and must not
 Loosen the latch and pull the plug
out.
 Loosen the strain relief screws  and
unlock the casing on both sides .
 Open the casing.
 Remove the stopper.