Installation
Installing a flush-fit hob with extraction and guided recirculation
mode
Create the worktop cut-out. Remember to maintain the minimum safety dis-
tances (see "Installation – Safety distances").
Solid wood, tiled and glass worktops:
Fix a wooden frame 5,5 mm below the top edge of the worktop (see "Installation
– Building-in dimensions for flush-fit installation").
Attach the sealing strip provided underneath the edge of the hob. Do not apply
the sealing strip under tension.
Feed the mains connection cable for the hob down through the worktop cut-out.
Centre the hob in the cut-out.
The gap between the ceramic glass surface and the worktop must be at least
2 mm wide. This is required so that the hob can be sealed.
Connect the hob to the mains electricity supply.
Check that the hob works.
Seal the gap between the hob and worktop with a silicone sealant that is heat-
resistant to at least 160 °C.
98