Installation
The veneer or laminate coatings of worktops (or adjacent kitchen
units) must be treated with 100 °C heat-resistant adhesive which will
not dissolve or distort. Any backmoulds must be of heat-resistant
material.
The crossbeams in front of the top area of the housing unit rear
wall must be removed for installation.
The hob must be installed such that the drip tray and the cleaning
flap are easily accessible and can be removed for cleaning.
The air duct is laid behind the housing unit rear wall. The rear wall
must be removable for maintenance purposes.
The minimum plinth height of the KMDA 7676 FL-U is:
- Extraction mode: no minimum plinth height required
- Guided recirculation mode: 100 mm
- Plug&Play mode: 25 mm
The exhaust air drawn into the vapour extraction may only be
routed through the base unit and back into the room in Plug&Play
mode. In extraction mode and in guided recirculation mode, the ex-
haust air must be routed outside through ducting (extraction mode)
or back into the room through the recirculation box (guided recircula-
tion mode).
Remember to maintain the minimum safety distances (see "Install-
ation – Safety distances").
76