Installation
Connection to window contact,
if required
The window contact connection
is live!
Danger of electric shock!
Disconnect the hob from the mains
electricity supply before connecting
the switching mechanism.
The connection cable for the
switching system must only be
connected by a suitably qualified and
competent electrician.
The connection cable for the
switching system must comply with
type H03VV-F 2 x 0.75 mm
must not exceed 2.0 m in length.
The switching system must be
equipped with a potential-free
contact suitable for 230 V, 1 A. The
extractor is switched off when the
switch is open.
Only use DIPT-approved and tested
radio switching systems (e.g. window
contact switches, pressure switches)
and have them approved by
authorised specialists (e.g. building
regulations inspector).
The switching system must be
suitable for use with a BLDC motor.
You will need the appropriate
external switching system
documents to safely connect and
operate the switch.
88
 Loosen the lug and pull the plug out.
2
and
 Loosen the strain relief screw  and
unlock the casing on both sides .
 Open the casing.
 Remove the stopper.