Connection to window contact,
if required
The window contact is
connected to the mains voltage!
Danger of electric shock!
Disconnect the cooktop from the
mains electricity supply before
connecting the switching
mechanism.
The connection cable of the
switching system must only be
connected by a suitably qualified and
competent electrician.
The connection cable of the
switching system must be of the
correct type and cross-sectional area
in strict accordance with current
national and local safety regulations
and must not exceed 2.0 m in length.
The switching system must be
equipped with a potential-free
contact suitable for 230 V, 1 A. The
extractor is switched off when the
switch is open.
Only use suitable switching systems
(e.g. window contact switches,
pressure switches).
The switching system must be
suitable for use with inductive loads
(BLDC motor).
Use switching systems in strict
accordance with current national and
local safety regulations.
 Loosen the lug and pull the plug out.
 Loosen the strain relief screw  and
unlock the casing on both sides .
 Open the casing.
 Remove the stopper.