11.2 Installation position
GEMÜ recommend installing the actuator vertically upright or
vertically down to optimise the service life.
11.3 Installation with butt weld spigots
Fig. 1: Butt weld spigots
1. Carry out preparations for installation (see chapter "Pre-
paring for installation").
2. Adhere to good welding practices!
3. Disassemble the actuator with the diaphragm before weld-
ing in the valve body (see "Removing the actuator"
chapter).
4. Weld the body of the product in the piping.
5. Allow butt weld spigots to cool down.
6. Reassemble the valve body and the actuator with dia-
phragm (see "Mounting the actuator" chapter).
7. Re-attach or reactivate all safety and protective devices.
8. Flush the system.
11.4 Installation with threaded sockets
Fig. 2: Threaded socket
NOTICE
Sealing material!
▶ The sealing material is not included in the scope of deliv-
ery.
Only use appropriate sealing material.
●
1. Keep thread sealant ready.
2. Carry out preparations for installation (see chapter "Pre-
paring for installation").
3. Screw the threaded connections into the pipe in accord-
ance with valid standards.
4. Screw the body of the product onto the piping using ap-
propriate thread sealant.
5. Re-attach or reactivate all safety and protective devices.
www.gemu-group.com
11.5 Installation with threaded spigots
Fig. 3: Threaded spigots
Thread sealant!
▶ The thread sealant is not included in the scope of deliv-
ery.
Only use appropriate thread sealant.
●
1. Keep thread sealant ready.
2. Carry out preparations for installation (see chapter "Pre-
paring for installation").
3. Screw the pipe into the threaded connection of the valve
body in accordance with valid standards.
ð Use appropriate thread sealant.
4. Re-attach or reactivate all safety and protective devices.
11.6 Installation with flanged connection
Fig. 4: Flanged connection
Sealing material!
▶ The sealing material is not included in the scope of deliv-
ery.
Only use appropriate sealing material.
●
35 / 68
11 Installation in piping
NOTICE
NOTICE
GEMÜ 543 eSyStep
OPEN / CLOSE (Code AE)