POINT A -
ELECTRIC CONNECTIONS
J1
L1 - N
230Vac 50/60Hz POWER SUPPLY (120Vac/60Hz UPON
REQUEST)
BLINKER (40 W MAX.)
J2
U
MOTOR COMMON CONNECTION
V-W
MOTOR PHASES AND CAPACITOR CONNECTIONS
J3
PED. BUTT.
PEDESTRIAN OPENING CONTACT (NO)
A+ TEST
+24Vdc SAFETY STRIP SELF-TEST POWER SUPPLY
LSC
CLOSE LIMIT SWITCH THAT CUTS OFF THE MOTOR IN CLOSING
COM
LIMIT SWITCH COMMON CONTACT
LSO
OPEN LIMIT SWITCH THAT CUTS OFF THE MOTOR IN OPENING
J4
STOP
STOP CONTACT (NC)
OPEN
OPENING CONTACT (NC)
CLOSE
CLOSING CONTACT (NC)
K. BUTT.
SINGLE PULSE CONTACT (NO)
A+
ACCESSORIES POWER SUPPLY +24Vdc
A-
ACCESSORIES POWER SUPPLY -24Vdc
SIGNAL
GATE OPEN INDICATOR 24Vdc
COM
COMMON CONTACT (common line for all the command and
safety inputs)
EDGE NC
SAFETY STRIP CONTACT (NC)
J5
AERIAL
RADIO ANTENNA
COM
COMMON CONTACT (common line for all the command and
safety inputs)
PHOTO NC
PHOTOCELLS CONTACT (NC)
J6
PROBE
Temperature sensor cable connection PROBE (Code ACG4665
optional)
J7
ENCODER
ENCODER connection (K PLUS operators)
J8
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER 24Vdc
S3
PROG.
PROGRAMMING BUTTON
TR1
LOW SPEED
ELECTRONIC REGULATOR FOR LOW SPEED ON APPROACH
TR2
TORQUE
ELECTRONIC TORQUE REGULATOR
(only CRX control board) DO NOT REMOVE ANY JUMPER!
SW
OTHERWISE THE OPERATOR WILL NOT WORK!
RADIO
NC: NORMALLY CLOSED CONTACT
NO: NORMALLY OPEN CONTACT
POINT B - SETTINGS
DIP 1
MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2
PROGRAMMING (See Point D)
DIP 1-2 STORAGE/DELETION OF RADIO CODES FOR COMPLETE OPENING (DIP 1 ON
followed by DIP 2 ON) (POINT F) ONLY FOR CRX MODELS
DIP 1-3 STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING (DIP 1
ON followed by DIP 3 ON) (POINT G) ONLY FOR CRX MODELS
DIP 2-1 PROGRAMMING OF PEDESTRIAN OPENING (See Point E)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Radio receiver STEP BY STEP
OFF - Radio receiver AUTOMATIC
DIP 5
ON - STEP BY STEP (OPEN-STOP-CLOSE-STOP-OPEN...)
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
OFF - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
DIP 6
ON - Photocells active only in closing
OFF - Photocells always active
DIP 7
ON - Encoder enabled for PLUS operator
OFF - Encoder disabled
DIP 8
ON - Blinker pre-flashing
OFF - Blinker normal flashing
S3
J5
TR1
TR2
J4
SW
S1
J3
J2
J1
SW S1
DO NOT REMOVE THE JUMPER! OTHERWISE THE OPERATOR
WILL NOT WORK!
SW1
DIP-SWITCHES
SW2
SW3
DIP 9
ON - Low speed in approaching DISABLED
OFF - Low speed in approaching ENABLED
DIP 10
ON - Electronic brake ENABLED
OFF - Electronic brake DISABLED
With K FCM it is mandatory to activate the electronic brake - DIP 10 on ON mode
DIP 11
ON - Gradual start ENABLED
OFF - Gradual start DISABLED
DIP 12
ON - Safety strip self test ENABLED
OFF - Safety strip self test DISABLED
DIP 13
ON - Motor operation control by external power relays (only for S1/R2 and S1/
R4 control boards). Encoder, low speed in approaching, gradual start
and electronic brake features, low speed and torque regulator will be
automatically disabled regardless their dip-switches and trimmers position.
OFF - Standard motor operation control without power relays
LOW SPEED
K800 PLUS
DIP 14
OFF
DIP 15
OFF
DIP 16
OFF
DIP 17
ON - close command after the transit through the photocell ENABLED
OFF - close command after the transit through the photocell DISABLED
DIP 18
ON - Working with motors 120V 60Hz
OFF - Working with motors 230V 50-60Hz
31
J7
J6
SW
RADIO
RADIO
J8
SW1
SW2
SW3
K1400 PLUS
K2200 PLUS
ON
OFF
OFF
ON
ON
OFF
G
B

Advertisement