GE Precision RXi Preinstallation Manual page 123

Table of Contents

Advertisement

GE M
S
EDICAL
YSTEMS
D
5142538 -100, R
IRECTION
EVISION
rf
GMM # GE Part #
cables description
C01
55779
5130863
Power supply OTS
C02
55784
5130864
Ground OTS
rf
GMM # GE Part #
cables description
C03
18878
5130865
High tension
C04
55783
5130866
Ground X-RAY Housing
X-Ray Housing thermal
C05
55782
5130867
switch
C06
55786
5130868
X-Ray Housing anode
C07
55993
5130869
VACUDAP chamber
C10
56400
5142373
Tube 2 indicator
rf
GMM # GE Part #
cable description
OTS parking position
C08
56194A 5130870
contacts
W07
56427
5142374
OTS sensor interface
rf
GMM # GE Part #
cables description
W01
56284
5130872
Ground
Wall bucky generator
W02
56283
5130873
interface
W03
56282
5130874
COMET AEC chamber
rf
GMM # GE Part #
cables description
W04
56357A 5130875-2 Wall bucky sensor interface
Wall bucky sensor interface
W05
56358B 5130876-2
extender
Page 18
6
Cables between OVERHEAD TUBE SUSPENSION (OTS) and MAIN SUPPLY PANEL for BASE SYSTEM
mt
ft
20
65,6 Main Power supply Panel MS4 (115 / 230 Vac) OTS - power supply - ST1 [L1 – N – GND]
20
65,6 Main Power supply Panel NE4 (GND)
Cables between OVERHEAD TUBE SUSPENSION (OTS) and GENERATOR CABINET for BASE SYSTEM
mt
ft
14,5 47,6 OTS - X-Ray Housing - anode, cathode
14,5 47,6 OTS -X-Ray Housing GND
OTS - X-Ray Housing thermal switch [Thermal
14,5 47,6
Switch]
14,5 47,6 OTS - X-Ray Housing anode [1 - 2 - 3]
14,5 47,6 OTS - Collimator - DAP
14,5 47,6 OTS - Collimator - M2- pin3, pin4
Cable between POSITIONER CABINET and OVERHEAD TUBE SUSPENSION (OTS) for BASE SYSTEM
mt
ft
OTS - Parking position Transversal
17,5 57,4
microswitch - MV1
OTS - Collimator remote PC board-
17,5 57,4
M33/M103/M104/F08
Cables between WALLBUCKY and GENERATOR CABINET for BASE SYSTEM
mt
ft
17,5 57,4 Main Power Supply Panel NE3 (GND)
Gen. cab. - room interface board
17,5 57,4
TB2/TB7/TB10/TB11
17,5 57,4 Gen. cab. - AEC interface board channel 2 - J2 Wall bucky - COMET chamber
Cables between WALLBUCKY and AUTOMATIC COLLIMATOR for BASE SYSTEM
mt
ft
17,5 57,4 Gen. Cab. - CM1 flex cable connector
OTS - Collimator remote PC board-
14,5 47,6
M33/M35/M58÷M65 – B0
P
RX
®
RECISION
I
AND
source
OTS - Ground – GND
source
Gen. cab. - Tank 2 - anode, cathode
Gen. cab. - Tank 2 - GND
Gen. cab. - (Tank 2) - [Tube2, Thermal
Switch]
Gen. cab. - (Tank 2) - [Tube2, Common -
Main - Shift]
Gen. cab. - DAP Interface board channel 2 -
J3
Gen. cab. - Room Inter. board TB8/TB4-
pin2, pin1
source
Pos. cab. - I/O board – 25S3SC2 pins 8-9
Pos. cab. - I/O interface board – 25S3CP13
source
Wall bucky - GND
Wall bucky - Bucky TB1
source
Wall bucky - Bucky TB1 – B1
Gen. Cab. - CM1 in-line flex cable connector
P
RX
®
S
RECISION
I
VERSION E
destination
mm inch
8
0.32
6
0.24
destination
mm inch
17
0.67 75x75x210
6
0.24
7
0.28
11
0.43
7
0.28 35x15 x 55 1.4 x.6 x 2.2
7
0.28
destination
mm inch
6
0.24
7
0.28 12 x 5 x 14 .47 x .2 x .55
destination
mm inch
6
0.24
11
0.43
8
0.32
destination
mm inch
8
0.32 35x15 x 55 1.4 x .59 x 2.2
8
0.32 35x15 x 55 1.4 x .59 x 2.2
D
YSTEM
RAWINGS
C \ mm
C \ inch
Crimped terminal
Crimped terminal
C \ mm
C \ inch
3 x 3 x 8.3
Crimped terminal
Crimped terminal
Crimped terminal
Crimped terminal
C \ mm
C \ inch
Crimped terminal
C \ mm
C \ inch
Crimped terminal
Crimped terminal
Crimped terminal
C \ mm
C \ inch

Advertisement