Characteristics
Power-ON start: ±0.01% ±50 ms max. (See note)
Accuracy of operating time
Signal start: ±0.005%±0.03 ms max. (See note)
and setting error (including
If the set value is within the sensor waiting time at startup the control
temperature and voltage
output of the H5CZ will not turn ON until the sensor waiting time passes.
influences)
Note: The values are based on the set value.
100 MΩ min. (at 500 VDC) between current-carrying terminal and
Insulation resistance
exposed non-current-carrying metal parts, and between non-continuous
contacts
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and
non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits
Dielectric strength
for all models except H5CZ-@D
2,000 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12
to 24 VDC
Impulse withstand voltage
4.5 kV (between current-carrying terminal and exposed non-current-
carrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC
±1.5 kV (between power terminals) and ±600 V (between input
Noise immunity
terminals), square-wave noise by noise simulator (pulse width: 100 ns/
1 µs, 1-ns rise)
Malfunction: 8 kV
Static immunity
Destruction: 15 kV
10 to 55 Hz with 0.75-mm single amplitude each in three directions for
Destruction
2 h each
Vibration
resistance
10 to 55 Hz with 0.35-mm single amplitude each in three directions for
Malfunction
10 min each
Destruction
300 m/s
Shock
resistance
Malfunction
100 m/s
10,000,000 operations min. (under no load at 1,800 operations/h and
Mechanical
ambient temperature of 23
Life
expectancy
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800
Electrical
operations/h and ambient temperature of 23
Weight
Approx. 105 g (Timer only)
* Refer to Life-test Curve.

Applicable Standards

UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14
conforms to EN61812-1 (Pollution degree 2/overvoltage category III)
B300 PILOT DUTY
Approved safety standards
1/4 HP 120 VAC, 1/3 HP, 240 VAC, 5 A resistive load
VDE0106/P100
CCC: Pollution degree 2, Overvoltage category II
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
EMC
Immunity Conducted Disturbance:
Immunity Burst:
Immunity Surge:
Immunity Voltage Dip/Interruption:
* The following safety standards apply to H5CZ.
cUL (Listing): Applicable when an OMRON P2CF (-E) Socket is used.
cUR (Recognition): Applicable when any other socket is used.
I/O Functions
For details, refer to the timing charts on page 16 and page 25.
Start signal
*
Inputs
Reset
Outputs
Control output (OUT)
* The H5CZ-L8E@ does not have an input.
2
in three directions, three cycles
2
in three directions, three cycles
°
C)
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 2)
EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
EN61000-4-4: 2 kV power-line (level 3);
EN61000-4-5: 1 kV line to lines (power and output lines) (level 3);
EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Normally functions to start timing.
In modes A-2 and A-3, disable timing. In mode S, starts and stops timing.
• Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode,
the present value returns to the set value.)
• Count inputs are not accepted and control output turns OFF while reset input is ON.
• Reset indicator is lit while reset input is ON.
Outputs take place according to designated operating mode when timer reaches corresponding set value.
*
C)
°
8 kV air discharge (level 3)
10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3)
1 kV I/O signal-line (level 4)
2 kV line to ground (power and output lines) (level 3)
Life-test Curve (Reference
Values)
1,000
500
100
DC30V L/R=7ms
50
AC250V/DC30V
cos =1
10
AC250V cos =0.4
0
1
2
3
4
A maximum current of 0.15 A can be switched at
125 VDC (cosφ =1) and a maximum current of 0.1
A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
*
,
H5CZ
5
Load current (A)
5

Advertisement