H5CZ
Timer
Operating Procedures
Setting Procedure Guide
Settings for Timer Operation
Use the following settings.
Settings for Twin Timer Operation
Refer to page 22.
* At the time of delivery, the H5CZ is set to the Timer configuration. Refer to page 25 for information on switching models.
Operating Procedures for Timer Function
• Change to Function Setting Mode.
Power ON
Run mode
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
From next page
To next page
12
*
*
* 1
3 s min.
Function setting mode
* 2
3 s min.
The characters displayed in reverse video are the default settings.
Set the time range using the
Time range
For details, refer to the Time Range List.
Set the timer mode using the
Timer mode
up
down
(UP)
(DOWN)
Set the output mode using the
Output modes
a
a-1
a-2
(A)
(A-1)
(A-2)
Note: Only modes A-2, b, E, and Z can be selected for models with instantaneous
contact outputs.
Set each digit for the output time using the corresponding
Output time
~
hold
0.01
(Output hold)
(0.01s)
(If the output time is set to 0.00,
Note: Displayed for modes A, A-1, A-2, A-3, b, b-1 and S only.
Set the input signal width using the
Input signal
width
20ms
1ms
(20ms)
(1ms)
Note: Not displayed for models with instantaneous contact outputs.
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
Instantaneous/
using the
Keys.
time-limit
1c1c
2c
(Instantaneous) (Time-limit)
Note: Displayed only for models with instantaneous contact outputs.
For details on operations in run mode, refer to page 15.
keys.
......
keys.
keys.
a-3
b
b-1
d
e
(A-3)
(b)
(b-1)
(d)
(E)
99.99
(99.99s)
hold
is displayed.)
keys.
Time Range List
Display
f
z
s
(F)
(Z)
(S)
keys.
Set Value
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to
99 min 59 s
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
1 h to 9999 h
0.001 s to
9.999 s