Applicable Wires - Omron H3DS Series Manual

Solid-state multi-functional timer
Hide thumbs Also See for H3DS Series:
Table of Contents

Advertisement

H3DS-jLC
Installation of Screwless Spring Terminal Models
Tools
A flat-blade screwdriver should be used to mount the cables.
Applicable Screwdriver
Flat-blade, Parallel-tip, 2.5 mm diameter
Flat-blade, Parallel-tip
2.5 dia.
Flat-blade, Flared-tip
Examples:
FACOM AEF.2.5
VESSEL No. 9900-(-)2.5
WAGO 210-119
WIHA 260/2.5

Applicable Wires

Applicable Wire Sizes
2
0.2 to 1.5 mm
, AWG24 to AWG16
Applicable Wire Type
Solid wires, stranded wires, flexible wires, or wires with ferules can
be used.
(See note 1) < 1.8
Diameter D (mm)
Conductor diameter d (mm) or length of sides a and b (mm)
Wires with Ferules
Note: 1. If the overall diameter of the wire is less than 1.8 mm, do
not insert the wire past the conductor. Refer to the fol-
lowing diagrams.
OK
2. If the overall diameter of the wire is over 2.8 mm, it will be
difficult to use double wiring.
Cannot be used.
75E
75
40
3.0 (see note 2)
NG
1.6
H3DS-jLC
33