Landscaping Block Enclosure Ventilation - Travis Industries Fire Garden 94900340 Manual

Fire pit burner
Table of Contents

Advertisement

20

Landscaping Block Enclosure Ventilation

If using landscaping block to build the enclosure use the included
key valve/ventilation assemblies to provide the required ventilation
for the enclosure.
The assemblies can accommodate 4" to 6" high block sizes.
Adjust the brackets on the assembly to accommodate heights
of more than 4 inches.
NOTE: The assemblies are designed to fit a 4" high x 8" wide
opening in the block. Two optional front plates can be added to
increase the size to 6" high x 12" wide. The plates can be trimmed
to accommodate sizes in between (see illustrations to the right).
The ventilation air for the enclosure MUST be drawn from
outdoor air only.
The vents must be located within 24" of the appliance.
The vents must be kept free from vegetation or debris that can
restrict the flow of air.
The vents must be installed on opposite sides from each other.
The vents must be installed in the first course of brick in the
enclosure.
© Travis Industries, Inc.
Installation
9/27/2023 - 1589
(qualified installers only)
 
VF Outdoor Fire Pit Burners