Direct-Run Wire Length Chart

This type of wire configuration allows for long distances between the transformer and the
appliances (see illustration below). Use the charts below to determine the correct wire gauge
and length.
24 Volt Lead 
 Wire 
  
min 
14 GA 
max 
min 
12 GA 
max 
min 
10 GA 
max 
* Not available on some transformers.

Wiring Examples:

Daisy-Chain Installations:

When using 3 appliances on one branch, 14 ga wire, and 150' of wire, use the 28V Lead.
When using 4 appliances on one branch, 10 ga wire, and 100' of wire, use the 24V Lead.

Direct Run Installations:

When using an appliance on a 200' run, 14 ga wire, use the 24V Lead.
When using 6 appliances, each on a 200' run, 14 ga wire, use the 24V Lead.
How to Determine Wire Gauge: When purchasing your wire, it should include a wire gauge (the larger the
number, the smaller the diameter wire). The wire will also be printed with a gauge number (e.g., AWG#14 = 14
gauge, 10AWG = 10 gauge, etc.). Do not use wires of dissimilar sizes (do not use 14-gauge & 10-gauge wire on
the same transformer).
© Travis Industries, Inc.
Installation
26 Volt Lead* 
 
  
 Wire 
 
0' 
 
14 GA 
242' 
 
0' 
 
12 GA 
369' 
 
0' 
 
10 GA 
566' 
 
9/27/2023 - 1589
(qualified installers only)
 
 
  
 
min 
79' 
 
max 
384' 
 
min 
120' 
 
max 
584' 
 
min 
184' 
 
max 
897' 
 
28 Volt Lead* 
 Wire 
  
min 
14 GA 
max 
min 
12 GA 
max 
min 
10 GA 
max 
1168' 
VF Outdoor Fire Pit Burners
  
234' 
499' 
356' 
760' 
548' 