Weatherproofing The Installation; Appliance Placement Requirements - Travis Industries Fire Garden 94900340 Manual

Fire pit burner
Table of Contents

Advertisement

Weatherproofing the Installation

This appliance is designed to withstand being installed outdoors in the elements; however, the enclosure will need
to be designed and constructed to withstand the same. The builder must provide a means for water to escape the
enclosure that is appropriate and specific to the site of the installation. This may necessitate improving ground
drainage, the fabrication of a drain pan, the creation of weep holes in the base of the enclosure, or building a roof
over the appliance (covers over the appliance must meet all the requirements detailed in this manual).

Appliance Placement Requirements

! For Outdoor Use Only. Install in well-ventilated areas.
The appliance is considered to be "outdoors" if installed with shelter no more inclusive than:
Walls on all sides, but with no overhead cover.
Within a partial enclosure that includes an overhead
cover and no more than two sidewalls. The sidewalls
may be parallel, as in a breezeway, or at right angles
to each other.
Within a partial enclosure that includes an overhead
cover and three sidewalls, so long as 30 percent or
more of the horizontal periphery of the enclosure is
permanently open.
The appliance must be installed on a level surface capable of supporting the appliance's weight.
The appliance setting on its legs can be placed directly on a wood or non-combustible surface.
The appliance should be located away from furniture and draperies.
The distance from the top of the burner to a ceiling above the appliance must be a minimum of:
84" (2134mm) for 10", 13", & 18" fire pits.
96" (2439mm) for a 22" fire pit
132" (3353mm) for a 32" fire pit
Do Not Locate the Appliance:
In high-traffic areas.
Under or near trees, plants, and buildings where debris may constantly fall into the appliance. Excessive debris
will require high maintenance and/or cause malfunctioning of the appliance.
In places where people or pets may contact the appliance. Guards or fences around the appliance in these
locations are recommended.
In places where the controls beneath the appliance may be submerged underwater. Submerging any part of its
controls may require the complete replacement of the controls.
© Travis Industries, Inc.
Installation
WARNING
9/27/2023 - 1589
(qualified installers only)
VF Outdoor Fire Pit Burners