Installation Warnings; Recommended Order Of Installation - Travis Industries Fire Garden 94900340 Manual

Fire pit burner
Table of Contents

Advertisement

Installation Warnings:

!
This appliance is designed for outdoor use only, in well-ventilated areas.
!
Failure to follow all the requirements may result in property damage, bodily injury, or even
death.
!
This appliance must be installed by a qualified installer.
!
This appliance is designed to operate on natural gas, or propane (LP).
!
This appliance requires a switched, 110v AC, GFCI (ground-fault circuit interrupter)
protected power supply. This circuit provides power to the 24v AC transformer.
!
Notify your insurance company before hooking up this appliance. All relevant information
on the appliance is located on page 2, Important Information. You provide them page 2.
!
The requirements listed below are divided into sections. All requirements must be met
simultaneously. The order of installation is not rigid – the qualified installer should follow
the procedure best suited for the installation.

Recommended Order of Installation

1. CAREFULLY PLAN THE INSTALLATION. Determine the location of the VF Fire Pit Burner and the controls.
Make sure all clearances will be met, (see page 14).
2. Run the gas line to the fire pit location. The appliance requires:
65,000 BTU input (NG or LP) for a 10" Burner.
125,000 BTU input (NG or LP) for a 13" Burner
175,000 BTU input (NG or LP) for an 18" Burner
225,000 BTU input (NG or LP) for a 22" Burner
350,000 BTU input (NG or LP) for a 32" Burner
3. Install the transformer and on/off switch and run low voltage wire to the fire pit location.
4. Frame the VF Fire Pit Burner enclosure (see page 17) OR construct the fire pit block enclosure (see page 18).
Install the key valve enclosure vent assemblies or separate key valve and vents at this time.
5. Convert the appliance to LP gas if applicable (see page 23).
6. Assemble the 4-piece base plate on the fire pit burner assembly (see page 21).
7. Run hard pipe or flex from the gas supply stub to the key valve.
8. Connect the 34" long flex line from the fire pit valve to the key valve.
9. Supply Electrical: The appliance uses 24VAC power and draws approximately 1.6 amps - Make sure the circuit
and wiring are appropriately sized (see diagrams starting on pg. 27.). If multiple appliances are powered through
a single switch the control modules for each of the individual appliances may be daisy-chained together. Make
sure to leave slack in the electrical line so the appliance or Fire Pit Burner assembly can be removed for service.
10. Bleed the gas line and briefly test fire the fire pit by switching on the electrical power to the control module. Leak
test the gas lines. Verify the appliance works correctly and that there are no gas leaks.
11. Place the fire pit assembly into the enclosure.
12. Finalize the installation. Install the crushed glass, crushed glass with an optional Bonfire log set (sold
separately), or tumbled stone media.
13. Give the manual to the homeowner and explain the operation of the appliance.
 
© Travis Industries, Inc.
Installation
9/27/2023 - 1589
(qualified installers only)
VF Outdoor Fire Pit Burners
9