Enclosure Ventilation Requirements

The fire pit enclosure must be ventilated to properly cool the fire pit (see illustration below for details).
The enclosure must be ventilated in accordance with the requirements listed below to allow the appliance
to cool. Failure to provide this ventilation will create a severe fire risk.
Enclosure Ventilation Overview
The fire pit enclosure rests on adjustable leveling legs that provide a minimum 1/2" gap on the bottom of the
enclosure. This 1/2" minimum gap must be maintained in order to provide cooling air to the appliance
components. Failure to maintain the gap will create a severe fire risk and will void the appliance warranty.
The height of the leveling legs can be adjusted by turning the leveling leg foot. The legs will adjust from 1/2"
to 1"
 
© Travis Industries, Inc.
Installation
(qualified installers only)
WARNING
5/24/22 - 1579
Outdoor Complete Linear Fire Pits