This symbol tells you what to tell the end-user. 2.1 Intended use The ZL19N control panel is engineered and built by Came Cancelli Automatici S.p.A. to command swing gate operators of the FERNI and FROG 24 V DC series. Any installation and use other than that specified in this manual is forbidden.
You can also connect: - the open door signal-lamp; - the cycle lamp; - the electro lock; - the 002LB18 for emergency operations in case of power outages. Types of defi nable commands: - opening/closing; -opening/closing with maintained action; - Partial opening; - partial stop;...
4.2 Main components Transformers Speed adjuster connectors Terminal board for connecting the 002LB18 card (if unused, make sure that bridges are connected among A-B; C-D; E-F; G-h) Accessories fuse Card fuse Amperometric sensitivity during travel adjustment trimmer Amperometric sensitity during travel adjustment trimmer Amperometric sensitivity during slowdown adjustment trimmer...
Page 5
5.2 Tools and equipment Make sure you have all the tools and materials needed to carry out the installation in total safety and in accordance with current regulations. Here are some examples. 5.3 Fastening and mounting the container 1) Secure the base of the panel in a safe area; yes max. 6 mm Head with to.
6 Electrical connections 2 EMEGA 24 V motors M1 N1 M2 N2 Power supply Opening limit switch Closing slowdown 1 EMEGA 24 V motor M1 N1 M2 N2 Closing Opening Power supply Shortcircuit slowdown limit switch...
Page 7
Accessories power source Terminals for powering accessories: - at 24 V (AC) with 230 V (AC) - at 24 V (AC) with 24 V (AC) Overall allowed power: 40 W 230 V AC powered, 50 / 60 Hz frequency Electro lock connection (12V-15 W max.) Lighting and warning devices Flashing-light (contact rated for: 24 V - 25 W max.
Page 8
Safety devices Delta-S C3 = (N.C.) "partial stop" contact Input for safety devices like photocells, and other devices that comply with EN 12978 regulations. Door stopping if it is moving with subsequent automatic closing. If unused set DIP switch n.8 to ON C1 = (N.C.) contact di riapertura durante la chiusura»...
Page 9
Command devices Stop button ((N.C.) contact.) - Door stopping button that excludes the automatic closing.To resume movement press the command button or trasmitter key. If unused set DIP switch n.9 to ON. Ket switch selector and/or opening button (N.O. contact) - Door opening command.
7 Selecting functions 10-WAY DIP-SWITCH UNCTION ACTIVATED 1 ON - Automatic closing - The automatic closing timer activates at the closing endpoint. The pre-set time is adjustable, but it's in any case subject to any safety device intervention and does not activate after a total "stop" or in case of power failure. 2 OFF - "Open-stop-close-stop"...
Page 11
8 Settings - END ADJ/SENS. * End adjustement of amperometric sensor during travel:min/max. - AMP SENS. * Adusts the amperometric sensitivity which controls the force developed by the motor during movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of travel.
Page 12
Adjusting the microswitch Swing the door until it is about 500 mm from its closed position. Turn the outer cam until the micro-switch is inserted, and lock it using the screw. Micro-switch Cam fastening screw Opening stop cam (see above for adjusting) Outer slowdown 500 mm A = Eff ective zone of the amperometric sensor with...
Adjusting travel and slowdown speeds For adjusting the travel and slowdown speeds, move the fastons onto the shown connectors. Warning!Travel and slowdoan speeds must the same on both transformer. M1 slowdown faston M2 slowdown faston M2 travel faston M1 travel faston 9 Activating the radio command Antenna POS.
Page 14
Radio frequency card Only for the AF43S / AF43SM radi-frequency cards. - position jumper as shown depending on the series of transmitters you are using. Frequency Card Series Radio-frequency transmitters FM 26,995 AF130 FM 30.900 AF150 AM 26.995 AF26 AM 30.900 AF30 AM 433.92 AF43S / AF43SM...
Page 15
Trasmettitori ATOMO AT01 • AT02 AT04 See instructions sheet in the packa- ge of the AF43SR radiofrequency card see instructions on box TOUCH TCH 4024 • TCH 4048 TOP-432A • TOP-434A TOP-432NA • TOP-434NA TOP-302A • TOP-304A TOP-862NA • TOP 864NA TOP-432S TWIN T132 •...
Page 16
Memorisation CH1 = Channel for direct function command to gearmotor control panel ("open only" command / "open-close-invert" command o "open-stop-close-stop", depending on selection made on DIP switches 2 and 3). CH2 = Channel for direct commands to an accessory device connected on B1-B2. 1) Keep CH1 button pressed on the electronic card.
Management System in compliance with the UNI EN ISO 14001 standard to ensure environmental protection. Please help us to safeguard the environment. At CAME we believe this to be one of the fundamentals in its market operations and development strategies. Just follow these short disposal instructions: DISPOSING OF THE PACKAGING The components of the packaging (i.e.
Page 18