  • Page 1 CONTROL PANEL 31 9 V2 1E N FOR 24 V GEARMOTORS INSTALLATION MANUAL ZL92 English...
  • Page 2 Warning Sings (e.g. gate plate). (i.e. that for which it was expressly built for). Any other use is Special instructions and to be considered dangerous. Came Cancelli Automatici S.p.A. advice for users is not liable for any damage resulting from improper, wrongful •...
  • Page 3 Intended use and limitations of use Intended use The ZL92 control panel is engineered to command 24 V DC operators for swing gates of the STYLO, MYTO, FROG-J and AMICO series. Any installation and use other than that explained in this manual are forbidden.
  • Page 4 Main component parts 1 -Transformer 2 -Card fuse 3 -Accessories fuse 4 -Display 5 -Memory roll card connector 6 -AF card connector 230V 7 -R700 or R800 card connector 8 -Lack of calibration warning LED indicator 9 -Programming buttons 10 -Terminal boards 11 -230 V power terminal boards 12 -Line fuse 13 -Current on-line warning LED indicator...
  • Page 5 Tools and equipment Make sure you have all of the tools and materials you will need to proceed with the installation in total safety, according to current rules and regulations. Here are some examples. Anchoring and mounting the box 1) Secure the base of the panel to a protected area; we suggest using cross slot Phillips head bolts of max.
  • Page 6 Electrical connections Cable types and sections Length of cable Length of cable Length of cable Connections Type of cable 1 < 10 m 10 < 20 m 20 < 30 m Control panel power supply 3G x 1,5 mm 3G x 1,5 mm 3G x 2,5 mm Power supply to motor* with encoder 3G x 1,5 mm...
  • Page 7 Command devices N.B. : insert the (R800) decoder card to have the (S7000) keypad selector recognised. 001S7000 – Keypad selector R800 CANCELLI AUTOMATICI 001LT001 - Magnetic card reader A B S1 GND 001TSP00 - Transponder sensor Black N.B. : insert the (R700) decoder card to have the (TSP00) sensor or (LT001) card reader recognised.
  • Page 8 Warning devices Open gate indicator-light (So- cket rating: 24 V – 3 W max.). It turns on when the gate is open. It turns off when the gate is closed (see function “F10”). Flashing light (socket Courtesy or cycle light (contact rated up to: rating: 24 V DC - 25 W 24V –...
  • Page 9 Confi gure either (N.C.) contacts CX or CY, DF with monitoring card input for safety devices such as sensate for DFI connections. edges, that comply with EN 12978 standards. See CX (F2 Function) or CY(F3 Function) input functions in: - C7 «re-open while closing», during gate closing, opening the contact causes inver- sion of movement until gate is fully open;...
  • Page 10 Programming Description of commands Display The ESC key is for: The ENTER key is for: - exiting the menu; < > ENTER - entering the menu; - cancelling modifications. - confirming and memorising set value. The < > keys are for: - shifting from one menu item to another;...
  • Page 11 Menu structure – “Total stop” Function – function assigned to CX input – function assigned to CY input – Safety test function – maintained action function – Command mode on 2-7 – Command mode on 2-3p – Obstacle detection function when motor is stopped F 10 –...
  • Page 12 IMPORTANT! Before setting adjusting any functions, set which gearmotors are installed in the system (A 1 – Motor type), check the gate’s proper direction of travel of (A 2 – Motors test) and calibrate the gate run (A 3 – Gate run calibration) Note: press ENTER to confirm after choosing each function value.
  • Page 13 Functions menu F 1 (Total Stop) : this function stops the gate and consequently excludes any automatic closing cycle; for movement to resume, you need to use the keypad or transmitter. Insert the safety device on [1 -2]; if unused, select “0” function. 0 = Deactivated;...
  • Page 14 F 7 (2-7Command) : setting the contact on 2-7 to step-by-step (open-close) or sequential (open-stop-close-stop). 0 = step-by-step (default setting); 1 = sequential. ENTER ENTER > > >...> F 8 (2-3P Command) : setting the 2-3P contact to pedestrian opening (second gate leaf opens fully) or partial (second gate leaf opens partially depending on the time setting of the percentage between 10 and 80 of the gate run, function “F36”).
  • Page 15 F 13 (closing thrust) : at the closing endpoint, the gearmotors give the gate leaves a brief final-closing thrust. 0 = Deactivate (default setting); 1 = 1. = Minimum thrust 2. = Medium thrust 3. = Maximum thrust ENTER >...> ENTER >...
  • Page 16 F20 (Automatic closing time after partial or pedestrian opening) : Automatic closing time of the gate leaf after a partial ope- ning or pedestrian command. Once this time has elapsed, the gate automatically closes and it is in any case conditioned by any safety devices that may be triggered, and is deactivated after a total safety “stop”...
  • Page 17 F 25 ( Courtesy light time) : supplementary light connected on (10-E), stays on while gate is opening and closing. The time can be set to between 60” and 180”. 60 = 60 seconds (default setting); 61 = 61 seconds ....; 180 = 180 seconds.
  • Page 18 F 31 (Slow-down speed of M2 motor) : setting the speed of the M2 motor during slow downs, calculated as a percentage. 20 = 20% motor slow-down speed (minimum); ....50 = 50% motor slow-down speed (default setting); ....60 = 60% motor slow-down speed (maximum). >...
  • Page 19 F 37 (Slow-down point when opening the M1 motor) : adjusts the point at which the M1 motor begins to slow down when ope- ning. The beginning slow-down point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down areas and points) 10 = 10% of the gate run;...
  • Page 20 F 43 (Point when M2 motor draws fully open) : adjusts the point at which the M2 motor begins drawing to the fully-open posi- tion. This point is calculated as a percentage of the full gate run (see paragraph illustrating the slow-down areas and points at which gate draws fully open or closed) 1 = 1% of the gate run;...
  • Page 21 User Menu U 1 (add user with assigned command) : add user (max. 25 users) assigned to a command via transmitter or other device (see paragraph on adding users with assigned command). 1 = step-by-step command (open-close); 2 = sequential command (open-stop-close-stop); 3 = open only command; 4 = pede- strian / partial opening command (see function “F8”;...
  • Page 22 Decoding cards To insert, change, remove users or to command the operator via radio command, insert the AF43S card. If using the transponder or card reader, insert the R700 card or, alternatively, the R800 card for the keyboard selector. Insert the memory roll to save and load all settings including users registered by another card. R700 R700 CANCELLI AUTOMATICI...
  • Page 23 Adding users with an assigned command Assigned Command user N.B.: Before proceeding, remove the memory roll card. 1) Select “U 1”. Press ENTER to confirm. < > ENTER 2) select command (1=step-by-step, 10 - 2=sequential, 3=open, 4=pedestrian / 11 - partial opening, 5= B1-B2 output contact) to assign to user via the greater-than and 12 -...
  • Page 24 Motor tests 1) Select “A2”. Press ENTER to confirm. < > ENTER 2) Select 1 to activate test. Press ENTER to confirm... < < < < > > > > ENTER 3) … “---” will be displayed, standing by - - - for a command…...
  • Page 25 Gate run calibration N.B: before proceeding with the calibration of the gate run, check that the area of movement is free of any obstacles and check that there is a mechanical stop or both opening and closing. Important! While calibrating, all safety devices will be disabled until the end of the calibration excluding the “total stop” 1) Select “A3”.
  • Page 26 Illustration of the slow-down areas and points at which gate draws to the fully open or closed position Note: the slow-down areas and points at which the gate draws to the fully open or closed position are tested according to the parameters set forth by Technical Norms EN12445 and EN12453 regarding compatibility of impact forces generated by moving gate leaves.
  • Page 27 UNI EN ISO 14001 standard to ensure environmental protection. Please continue our efforts to protect the environment - which CAME considers one of the cardinal elements in the development of its operational and market strategies - simply by observing brief recommendations as regards disposal: DISPOSAL OF PACKAGING The packaging components (cardboard, plastic, etc.) are all classifiable as solid urban waste products and may be disposed of easily,...
  • Page 28 HR • Za sve dodatne informacije o poduzeću, proizvodima i tehničkoj podršci: UK • Для отримання будь-якої іншої інформації про компанію, продукцію та технічну підтримку: www. came.com www. came.com CAME Cancelli Automatici S.p.A. CAME Cancelli Automatici S.p.A. Via Martiri Della Libertà, 15 31030 Dosson Di Casier...