8 Maintenance and care
8.1 Maintenance
To ensure the correct function, safety and service life of the device the following points must be
executed in the maintenance interval.
Used only original spare parts, otherwise the warranty expires.
For all operations you have to make sure, that the device will not close unintended.
Danger of injury!!!
All operations may only be made in closed state of the device!
MECHNICAL
Service interval
First inspection after
25 operating hours
After 50 operating hours
Minimum 1x per year
(at rough conditions
shorten the interval)
AUTOMATIC-RELEASE
Never grease the automatic-release, if necessary use oil!
Maintenance work
●
Control and tighten all screws and connection.
(The implementation is only allowed by an expert).
●
Tighten all screws and connection (Take care that the tightening torques
according to the property class of the screws are observed).
●
Check all joints, bolts, guidance's and gears for correct function, if
necessary adjust or replace it.
●
Check all Grippers ( if available) for signs of wear.
●
Grease all slidings ( if available) when the device is in opened position
with a spatula.
●
Check of all the suspension parts, bolts and straps. Check for corrosion
and safety by an expert.
12/01/10