Removing Errors; Repairs - probst FTZ-I Translation Of Original Operating Instructions

Grab for prefabricated concrete products
Hide thumbs Also See for FTZ-I:
Table of Contents

Advertisement

Maintenance and care
FTZ-I
V1

8.2 Removing errors

ERROR
The clamping-power is not big
enough, the load is slipping
out
(optional)
(optional)
(Adjustment of the opening width)
(optional)
Unbalanced load
(Adjustment of the opening width)
(optional)
Automatic release does not
work
mechanical
(optional)

8.3 Repairs

Only persons with the appropriate knowledge
and ability are allowed to repair the device
CAUSE
The grippers are worn
The maximum load is exceed
The actual opening width is
not correct
The device is not loaded
symmetrically
The adjustment of the opening
width is not symmetrical.
Automatic release does not
work
Replace the grippers
Reduce the weight of. the load
Adjust the opening width
according to the load you want
to transport
Adjust the position of the load
Correct the adjustment of the
opening width
Clean automatic release with
high pressure-cleaner
Oil the automatic release
(never with grease)
Change the inset of the
automatic release
Before the device is used again, it has to be
checked by an expert.
12/01/10
18 / 20
REPAIR

Advertisement

Table of Contents
loading

This manual is also suitable for:

5310.0120

Table of Contents