CAREL Easy Milk Chiller
Setting the Setpoint (desired temperature)
STEP ACTION
1
Press T1/T2 Button for more than 3 secs
Select T1
2
Press SET for 1s: current value will display
3
Press UP or DOWN to change the value
4
Press SET to confirm the new value
Accessing and Setting the Parameters Types F and C
1
Press SET for 3 s; "PS" will display (Password is requested)
2
- to access type F & C parameters enter the password "22" using UP/DOWN
- to access type F only, press SET (without entering the password)
3
Scroll inside the menu by using UP/DOWN
4
to display/set the values of the parameter displayed press SET,
then UP/DOWN and finally press SET to confirm the changes
5
to save all the new values and exit the parameter menu, press SET for 3 s:
to exit without saving the changed values do not press any button for at least 60 s;
Parameter Folders
/ PROBE
r CONTROL
c COMPRESSOR
A ALARM
P AGITATOR
H OTHER SETTINGS
Parameter Types
F Frequent
C Configuration