Operating of Working Levels

Deep cool

Press the 'COOLING' button twice activates the T2,
(Deep cool, function: default 2°C)
Stirring in cooling mode = INTERMEDIATE STIRRING
Briefly press 'AGITATOR' in cooling mode:
A short intermediate stirring period [duration = C23] is triggered.
Press 'AGITATOR' in cooling mode for around 5 seconds:
A long intermediate stirring period [duration = C24] is triggered.
See also the section: 'Intermediate stirring options'.

Cleaning mode

Press 'WASHING' button: (out of OFF mode)
The cleaning program will be carried out automatically according to your
default settings. Depending on the setting in [r97], the display indicates
the current cleaning stage or the temperature.

Quick wash

• Press the 'QUICK WASH' button for 3 seconds
The "Quick Wash" cleaning program will be carried out
automatically according to preset default settings.

Descale

• Press the 'DESCALE' button for 3 seconds Automated descale
can be activated using r7
Special function for commissioning / Service
For commissioning- and Service purposes all rinsing steps can be
manually switched.