Cooling Parameters
Code 212: GENERAL COOLING PARAMETERS C
Parameter
Temperature Settings
C1
C2
C10
C11
Agitator Settings
C20
C21
C23
C24
C25
Cooling Time Monitoring
C81
Sensor Setting
C90
C91
Software Version
C98
Code 345
EXTENDED COOLING PARAMETERS
Parameter
Setting Range Limit
P10
P11
P12
P13
P15
P16
P17
P18
Setting Agitator
P22
Setting Cooling Start
P62
Setting Compressor
P71
Setting Deep Cool
P81
Description
Target temperature T1
Target temperature T2 (Deep cool)
Differential for T1
Differential for T2 (Deep cool)
Duration of after-stirring
Pause duration
Duration of 'intermediate stirring SHORT'
Duration of 'intermediate stirring LONG'
Maximum continuous stirring period in OFF mode
Maximum cooling time for first milking
Display actual temperature
Sensor correction
Software version
The software version installed is shown to help service technicians.
Description
Lower limit for target temperature T1
Upper limit for target temperature T1
Lower limit for target temperature T2 (Deep cool)
Upper limit for target temperature T2 (Deep cool)
Lower limit for differential T1
Upper limit for differential T1
Lower limit for differential T2 (Deep cool)
Upper limit for differential T2 (Deep cool)
Function intermediate stirring
0: deactivated
1: short / long
Duration of cooling start delay
Minimum pause time compressor
Duration of T2 deep cool
Range
2,0
–
12,0 °C
2,0
–
12,0 °C
0,1
–
2,0 °C
0,1
–
2,0 °C
0-999 sec
0-999 min
1-60 min
1-60 min
1
-
60 min
0
- 999 min
-10 to +10k
P
Range
0
–
50.0 °C
0
–
50.0 °C
0
50.0 °C
0
–
50.0 °C
0.1 –
30.0 °C
0.1 –
30.0 °C
0.1 –
30.0 °C
0.1 –
30.0 °C
0 or 1
0...999 min
0...999 sec
0...100 min
LE-200 Default
4,0
2,0
0,5
0,2
60
15
2
5
7
0
LE-200 Default
2
8
2
8
0.1
2
0.1
2
1
30
120
30
LE-200