18

Adjustment of Cleaning Step Times

Step Times
Main Wash: 'n' parameters
Descale Wash: 'd' parameters
Quick Wash: 'u' parameters
The step times as set in Parameters r1, r2 and r3 are fixed and cannot be altered.
USER DEFINED PROGRAM TIMES
But should it be necessary to make adjustments this can be done selecting
Parameter 'r4'
How to proceed
• Parameter 'r4' is used to make a copy of the wash programs 'r1', 'r2' and 'r3'
• Set 'r4' to position '2'
• This makes a copy of the programs under 'r1', 'r2' and 'r3'
• Hold the UP and DOWN buttons simultaneosly for 3 secs to save
• Proceed to change the required step times by entering the relevant
ACCESS CODE
• Now you can proceeed to change the step times in 'n', 'd' and 'u' parameters
• After every change, hold the UP and DOWN buttons simultaneosly
for 3 secs to save
• After all changes are complete Set 'r4' to position '1'
• 'r4' position '1' now contains the active cleaning programs
• To revert to the original default programs set 'r4' back to '0'
CODE
Code: 111
Code: 222
Code: 333