Power Failure During The Cleaning Process; Service Functions For Testing The Cleaning Cycle - Liscarroll Engineering LE-200 Installation And Operating Instructions Manual

Universal tank controller
Table of Contents

Advertisement

Power failure during
the cleaning process
Service functions for
testing the cleaning cycle
16
Cleaning Program Description
After return of voltage in case of a power failure:
• display shows the current temperature
• drain valve is opened for the time [n70]
• control continues the cleaning at the start of the cleaning stage in which
the interruption happened
• control switches into the OFF-mode .
Start cleaning with the desired cleaning stage
• Press CLEANING button: A cleaning cycle starts with the selected cleaning
stage and then runs through to the end.
• The next cleaning cycle starts again with the first cleaning stage.
Switch on the cleaning cycle with single step function
In order to be able to test a cleaning cycle more quickly, it is possible to switch the
cycle manually from one program step to the next without having to wait until it
has been completely processed.
• First, set the 'Display during Cleaning parameter 'r97' to '0'.
• By repeatedly pressing the CLEANING button, the cycle can now be
progressed step by step.
• Can be terminated via OFF button at any time, with drain phase.
• When finished set 'r97' back to '4'.