Power failure during
the cleaning process
Service functions for
testing the cleaning cycle
16
Cleaning Program Description
After return of voltage in case of a power failure:
• display shows the current temperature
• drain valve is opened for the time [n70]
• control continues the cleaning at the start of the cleaning stage in which
the interruption happened
• control switches into the OFF-mode .
Start cleaning with the desired cleaning stage
• Press CLEANING button: A cleaning cycle starts with the selected cleaning
stage and then runs through to the end.
• The next cleaning cycle starts again with the first cleaning stage.
Switch on the cleaning cycle with single step function
In order to be able to test a cleaning cycle more quickly, it is possible to switch the
cycle manually from one program step to the next without having to wait until it
has been completely processed.
• First, set the 'Display during Cleaning parameter 'r97' to '0'.
• By repeatedly pressing the CLEANING button, the cycle can now be
progressed step by step.
• Can be terminated via OFF button at any time, with drain phase.
• When finished set 'r97' back to '4'.