HART
Handheld DD
®
Installation & Operation Manual
MT3809G Series
Variable Area Flow Meters
Beyond Measure

Advertisement

loading
Need help?

Need help?

Do you have a question about the HART MT3809G Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Brooks HART MT3809G Series

  • Page 1 HART Handheld DD ® Installation & Operation Manual MT3809G Series Variable Area Flow Meters Beyond Measure...
  • Page 3: Table Of Contents

    Contents Brooks Instrument Section 1 Introduction Description ............................4 Section 2 Installation Device Configuration ........................5 Section 3 Operation Start Communication ........................11 Example - Access Process Variables .................... 12 Example - Verify Tag Number ....................... 12 Example - Verify Engineering Units and Range ................13 Example - Set Low Alarm to Enable ....................
  • Page 4: Description

    Section 1 Introduction Brooks Instrument Description This document will describe the procedure for removing the existing 3809 Device description (DD) and installing the 3809G DD to the 475 HART Handheld (HH) using the SD card from the 475HH and the “Easy Upgrade Utility” program.
  • Page 5: Section 2 Installation

    Section 2 Installation Brooks Instrument Device Configuration This section contains the procedures for the installation of the 3809G DD. a. Copy supplied 3809G DD files to location: <Easy Upgrade Utility installation folder*>\MMI\Field Communicator Easy Upgrade Utility 3.6\PC Database\DD\HART\en *note: the actual <Easy Upgrade Utility installation folder*> depends on original user installation of the Easy Upgrade Utility, e.g.
  • Page 6 Section 2 Installation Brooks Instrument g.This screen will be visible when connected: h. Select “More Options” Manual HART Communications for MT3809G...
  • Page 7 Brooks Instrument i. Go to “DDs” option. j. On the card reader look for DD named “Brooks Instrument 38xxVA Rev 1 DD1” k. Check the box and select “Remove” l. Check if DD “Brooks Instrument 38xxVA Rev 1 DD1” was removed...
  • Page 8 Section 2 Installation Brooks Instrument m. Go to the PC data base and look for DD: “Brooks Instruments 38xxVA Rev 1 DD 2” n. Check the box and answer YES to the pending question (Check an untested package?) o. Press the “arrows” for transferring the DD to the card reader...
  • Page 9 Section 2 Installation Brooks Instrument p. Confirmation will be received when the new DD is installed on the card reader q. DD can be seen in the card reader location Manual HART Communications for MT3809G...
  • Page 10 Section 2 Installation Brooks Instrument r. Select “Disconnect” s. Remove the SD card from the computer t. Install the SD card into the 475HH u. HART communication with the model 3809G is now available Manual HART Communications for MT3809G...
  • Page 11: Start Communication

    Section 3 Operation Brooks Instrument Start Communication a. Select “CONT” Manual HART Communications for MT3809G...
  • Page 12: Example - Access Process Variables

    Section 3 Operation Brooks Instrument Example - Access Process Variables: Example - Verify Tag Number: Manual HART Communications for MT3809G...
  • Page 13: Example - Verify Engineering Units And Range

    Section 3 Operation Brooks Instrument Example - Verify Engineering Units and Range Example - Set Low Alarm to Enable: Manual HART Communications for MT3809G...
  • Page 14 BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service and support to back it up. We operate first class repair facilities located around the world to provide rapid response and support.