Brooks SLA5850 Installation And Operation Manual

Brooks SLA5850 Installation And Operation Manual

Mass flow meters
Table of Contents

Advertisement

Installation and Operation Manual
X-TMF-SLA5800-MFC-eng
Part Number: 541B027AAG
April, 2013
®
Brooks
SLA5850, SLA5851, SLA5853
Mass Flow Controllers Models
and Models SLA5860, SLA5861, SLA5863
Mass Flow Meters
Model SLA5850D
DeviceNet
with Coplanar Valve
Model SLA5853S
Analog I/O MFC
with RS-485
Digital I/O
TM
MFC
Model SLA5850S
Analog I/O MFC
with RS-485
®
Brooks
Digital MFC's & MFM's
Model SLA5850F
Digital I/O
F
Fieldbus MFC
OUNDATION
with Coplanar Valve
Model SLA5850S
Analog I/O MFC
with RS-485
Elastomer Downport

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLA5850 and is the answer not in the manual?

Questions and answers

Summary of Contents for Brooks SLA5850

  • Page 1 Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 ® Brooks SLA5850, SLA5851, SLA5853 Mass Flow Controllers Models and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters Model SLA5850D Model SLA5850F Digital I/O Digital I/O DeviceNet...
  • Page 2 Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013...
  • Page 3 We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing, and more.
  • Page 4 Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 5: Table Of Contents

    Contents Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG Brooks ® Digital MFC's & MFM's April, 2013 Paragraph Page Number Number Section 1 Introduction Scope ............................1-1 Purpose ............................1-1 Description ..........................1-1 Specifications ..........................1-2 Section 2 Installation General ............................2-1 Receipt of Equipment .........................
  • Page 6 Number Open Collector Alarm Output..................... 1-6 General Wiring ........................... 1-6 Response Performance of Brooks Digital MFC ................. 1-7 Linear Ramp-up and/or Ramp-down from 200% Per Second Down to 0.5% Per Second Setpoint Change .................... 1-7 Model SLA5850D Digital I/O DeviceNet MFC ................1-11 Model SLA5850S Analog I/O MFC with RS-485 Elastomer Downport Connections ....
  • Page 7: Section 1 Introduction

    The SLA5800 Series covers an extremely broad range of flowrates. Model SLA5850 can have a full scale flow as low as 3 ccm. With a high turndown ratio of 50:1, accurate gas flow can be measured or controlled down to 0.06 ccm! Model SLA5853 can meter or control gas flow up to 2500 lpm.
  • Page 8: Specifications

    1-4 Specifications PERFORMANCE CHARACTERISTICS: Flow Ranges Models SLA5850/SLA5860 - Any FS range from 0-3 ccm to 0-50 lpm (N eq.) Models SLA5851/SLA5861 - Any FS range from 20-100 lpm (N eq.) Up to 200 lpm H...
  • Page 9 (2) Max. Delta P for 5853 is 20 bar (300 psi). (3) 70 bar / 1000 psi for UL Certification. Pressure Differential Range (Controllers) Minimum: Model SLA5850 5 psi (0.35 bar) up to 50 lpm (N eq.) Model SLA5851 10 psi (0.69 bar) from 30 lpm to 100 lpm (N eq.)
  • Page 10 Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 PHYSICAL: Materials of Construction ® Wetted parts - stainless steel with Viton fluoroelastomers ® ® Optional: Buna-N, Kalrez , Teflon /Kalrez and EPDM...
  • Page 11 Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 supported. Setpoint input types are software selectable as follows: 0 - 5 Vdc 1 - 5 Vdc 0 - 20 mA...
  • Page 12: Open Collector Alarm Output

    Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 0.3 Vdc > VOR > 4.8 Vdc: Undefined Valve Override Signal Specifications (Analog I/O Versions only) Input Impedence: 800 kΩ Absolute Max. Input: -25 Vdc > VOR > 25 Vdc...
  • Page 13: Response Performance Of Brooks Digital Mfc

    Traditional soft start or linear ramp-up and/or ramp-down (See Figure 1-4) can be factory selected or are available via the Brooks Service Suite Linear ramp-up is adjustable at 200% per second down to 0.5% per second setpoint change.
  • Page 14 Refer to Table 1-3 (Analog I/O pin connections), that enables the device to communicate via a personal computer for process control. Baud rate selections for the Brooks Digital Series related to RS-485 are: 1200, 2400, 4800, 9600, 19200 and 38400 baud and can be selected via the Brooks service Suite The RS-485 is essentially a multidrop connection.
  • Page 15 Digital MFC's & MFM's April, 2013 DeviceNet Communications The Brooks SLA5800 Digital Series is also available with DeviceNet communication capability. DeviceNet is an open digital protocol capable of high speeds and easy system connectivity. Brooks Instrument has several of its devices available on this popular networking standard, and is a...
  • Page 16 See Table 1-1 for further pressure information PC-based Support Tools Brooks Instrument offers a variety of PC-based process control and service tools to meet the needs of our customers. SmartDDE may be used with any unit supporting RS-485 in a multidrop configuration, thus allowing users to control and monitor their Brooks devices.
  • Page 17: Model Sla5850D Digital I/O Devicenet Mfc

    Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure1-5 Model SLA5850D Digital I/O Devicenet MFC Figure 1-6 Model SLA5850S Analog I/O MFC with RS-485 Elastomer Downport Connections 1-11...
  • Page 18: Model Sla5850F Digital I/O Foundation Fieldbus Mfc With Coplanar Valve

    Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure 1-7 Model SLA5850F Digital I/O F Fieldbus MFC with Coplanar Valve OUNDATION Figure 1-8 Model SLA5851D Digital I/O DeviceNet MFC...
  • Page 19: Model Sla5853 Analog I/O Mfc With Flanged Connections

    Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure 1-9 Model SLA5853F Digital I/O F Fieldbus MFC OUNDATION Figure 1-10 Model SLA5853S Analog I/O MFC with Flanged Connections 1-13...
  • Page 20: Model Sla5860S Analog I/O Mfm With Rs-485

    Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure 1-11 Model SLA5860S Analog I/O MFM with RS-485 Figure 1-12 Model SLA5861F Digital I/O F Fieldbus MFM OUNDATION 1-14...
  • Page 21: Model Sla5863 Analog I/O Mfm With Flanges

    Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure 1-13 Model SLA5863D Digital I/O Devicenet MFM Figure 1-14 Model SLA5863 Analog I/O MFM with Flanges 1-15...
  • Page 22 Section 1 Introduction Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 THIS PAGE WAS INTENTIONALLY LEFT BLANK 1-16...
  • Page 23: Section 2 Installation

    Brooks Digital MFC's & MFM's April, 2013 2-1 General ® This section provides installation instructions for the Brooks Digital MFC's and MFM's. Section 1, Figures 1-5 thru 1-12 show the dimensions and electrical connections. 2-2 Receipt of Equipment When the instrument is received, the outside packing case should be checked for damage incurred during shipment.
  • Page 24: Return Shipment

    Digital MFC's & MFM's April, 2013 2-4 Return Shipment Prior to returning any instrument to the factory, contact your nearest Brooks location for a Return Materials Authorization Number (RMA#). This can be obtained from one of the following locations: Brooks Instrument 407 W.
  • Page 25: In-Line Filter

    40 micron SLA5853/63 > 100 lpm Consult factory Note: Brooks provides many filter options. For those not listed here, please contact factory. 2-9 Installation Recommended installation procedures: a. The Brooks Digital MFC or MFM should be located in a clean, dry atmosphere relatively free from shock and vibration.
  • Page 26 Special considerations to be taken when installing the SLA5853 MFC: The Model SLA5853 has a valve design that is different from the standard low flow Brooks TMFC's. The SLA5853 consists of a dual stage, pilot operated valve. The pilot valve (located on the top of the MFC) controls a differential pressure across the main valve which, in turn controls the flow through the device.
  • Page 27: Electrical Interface

    For more information, please contact the Brooks Technical Service group. 2-10 Electrical Interface The setpoint signal is supplied as a 0(1) to 5 Vdc or 0(4)-20 mA analog signal.
  • Page 28: D-Connector Shielded Cable Hookup Diagram, Voltage I/O Version

    GRN/WHT RS-485, Common A (+) Input/Output BLU/WHT * Brooks Read Out Models 0151, 0152, 0154, 0254 See Table 3-1 for Resistor values Figure 2-1 D-Connector Shielded Cable Hookup Diagram, Voltage I/O Version Figure 2-2 Common Electrical Hookups, Voltage I/O Version...
  • Page 29 Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure 2-3 Recommended I/O Wiring Configuration for Current Signals (Non-Isolated Power Supply) Figure 2-4 Recommended I/O Wiring Configuration for Current Signals (Isolated Power Supply)
  • Page 30: Rs-485 Multidrop Interconnection Tmfs And Pc

    Section 2 Installation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure 2-5 RS-485 Multidrop Interconnection TMFs and PC The RS-485 is a multidrop connection and allows a maximum of 32 devices to be connected to a computer system. IBM-ompatible PCs are not equipped with RS-485 ports as standard.
  • Page 31: Operation Check Procedure (Analog I/O)

    Section 2 Installation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 2-11 Operation Check Procedure (Analog I/O) a. Mount the MFC/MFM in its final orientation. b. Apply power to the MFC/MFM and allow approximately 45 minutes for the instrument to completely warm up and stabilize its temperature.
  • Page 32: Digital I/O: Devicenet Or Foundation Fieldbus

    PRODUCED from the device (MFC) as an INPUT into the network or the data is being CONSUMED by the device (MFC) is an OUTPUT from the network). The Brooks MFC supports 12 instances of Input Assemblies and 4 instances of Output Assemblies.
  • Page 33: Section 3 Operation

    Section 3 Operation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 3-1 Overview This section contains the following information: • Theory of Operation • Features 3-2 Theory of Operation for Flow Measurement The thermal mass flow measurement system consists of two components: the restrictor and the flow sensor.
  • Page 34: Features

    Digital MFC/MFMs perform much like traditional analog MFCs, but with improved accuracy, step response and valve control. The analog interface matches that of Brooks' popular analog MFCs so it can be retrofitted into tools using analog MFCs. Other versions of the Delta Class can provide a variety of digital protocols, for example DeviceNet and RS-485.
  • Page 35: Flow Sensor Operational Diagram

    Section 3 Operation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Figure 3-1 Flow Sensor Operational Diagram (VCR End Connections Shown) Zero Button Figure 3-2 Externally Accessible Adjustment for all Meters/Controllers.
  • Page 36: Analog I/O Mode Of Operation

    Digital MFC's & MFM's April, 2013 3-4 Analog I/O Mode of Operation The following paragraphs describe the basic features of the Brooks Digital Series Mass Flow Meters/Controllers. NOTE: Read Section 3-3, Features, before reading this section. See DeviceNet Supplemental Instruction Manual for specific details on communication features.
  • Page 37 Section 3 Operation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Valve Override (MFC Only) Connector Pin 12 on the 15 pin D-Connector allows the valve to be forced to its most closed state or its most open state, regardless of setpoint. If this input is not electrically connected, the MFC will operate according to the current values of the other MFC inputs.
  • Page 38: Communications Features

    Digital communication, designed to emulate the Brooks S-series "S-protocol" or pseudo-HART communications is available on the Brooks Digital Series via RS-485. This form of multi-drop capable communication provides access to many of the Brooks Digital Series functions for "control and monitor" operations, including: •...
  • Page 39 Digital MFC's & MFM's April, 2013 3-5-2 DeviceNet Communications Features The Brooks SLA5800 Digital Series is also available with DeviceNet communication capability. DeviceNet is an open digital protocol capable of high speeds and easy system connectivity. Brooks Instrument has several...
  • Page 40: Alarms And Warnings (Analog Versions Only)

    Alarms and Warnings are a user configurable feature. This feature may be adjusted via the Service Port using a special software application available from Brooks. Reference the Brooks Service Suite User Manual for more information about the Service Port and Service Tool software applications.
  • Page 41 Section 3 Operation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 Latching Enable - When an alarm/warning is set to non-latching, that means the alarm is indicated only when the monitored value exceeds the specified conditions.
  • Page 42: Diagnostic Alarms (Analog Versions Only)

    Section 3 Operation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 3-6-2 Diagnostic Alarms (Analog versions only) A Diagnostic Alarm will be indicated when any of the diagnostics below detect a failure providing a visual indication via the red and/or green LED, and activating the TTL open collector output located on the 15 pin D-Connector.
  • Page 43: General Alarms And Warnings (Analog Versions Only)

    Section 3 Operation Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 3-6-3 General Alarms and Warnings (Analog versions only) Several alarms are available to indicate unexpected process control events as follows: Flow Alarms Two flow alarms will be provided.
  • Page 44: Calibration/Configuration Sets

    Calibration and configuration data sets may be adjusted by an advanced user via the Service Port using a special software application available from Brooks. Reference the Brooks Service Suite User Manual for more information about the Service Port and Service Tool software applications.
  • Page 45: Special Features

    Special Features may be adjusted by an advanced user via the Service Port using a special software application available from Brooks. Reference the Brooks Service Suite User Manual for more information about the Service Port and Service Tool software applications.
  • Page 46: Flow Signal Lock-In

    I/O versions only) may be used to monitor, diagnose, tune and calibrate Brooks devices. The Brooks Service Suite interfaces with Brooks products via a special service port. The Brooks Service Tool (BST) may be used for devices equipped with digital communications to perform many of the same tasks as the Brooks Service Suite.
  • Page 47: Section 4 Maintenance & Troubleshooting

    Part Number: 541B027AAG Brooks ® Digital MFC's & MFM's April, 2013 4-1 Maintenance and Troubleshooting No routine maintenance is required on the Brooks Digital MFC's and MFM's. If an in-line filter is used, the filtering elements should be periodically replaced or cleaned.
  • Page 48: Troubleshooting Analog Or Devicenet Version

    Section 4 Maintenance & Installation and Operation Manual X-TMF-SLA5800-MFC-eng Troubleshooting Part Number: 541B027AAG Brooks ® Digital MFC's & MFM's April, 2013 4-1-1 Troubleshooting Analog or DeviceNet version This section contains suggestions to help diagnose MFC related problems in the gas distribution system and answers commonly asked questions.
  • Page 49 The LED labeled 'NET' is used to indicate NETWORK status. Note the 'NET' LED can have 4 distinct operational states. For more complete details on these LEDs, reference the Brooks DeviceNet Supplement Instruction Manual. Q: What is purpose of the Rotary Switches on top of the MFC? A: Two of the rotary switches are labeled 'ADDRESS'.
  • Page 50: System Checks

    Nominal 580 ohm reading. 4-1-2 System Checks The Brooks Digital Series Flowmeters and Controllers are generally used as a component in gas handling systems, which can be complex in nature. It can therefore be very difficult to isolate a malfunction in the system. An inaccurately diagnosed malfunction can cause many hours of unnecessary downtime.
  • Page 51 Bench Troubleshooting 1. Establish a proper connection between the Brooks Digital Series Mass Flow Meter or Controller (using Figure 4-1 as a reference) Switch on the power and allow the instrument to warm-up for 45 minutes. In case of a Controller model, adjust the Setpoint to zero.
  • Page 52: Cleaning Procedures

    4-1-4 Calibration Procedure The calibration of Brooks Digital Series Mass Flow devices is not described in this manual. Such calibration requires accurate and traceable calibration equipment such as Brooks Vol-U-Meter ®...
  • Page 53: Troubleshooting

    (regardless of Setpoint) and (Section 4-1-2). there is flow through the meter/controller Defective electronic board Contact Brooks Instrument Flow cannot be achieved Clogged Control Valve Clean the control valve (Section 4-1-2) or regardless of Setpoint. return the device to the factory...
  • Page 54 Section 4 Maintenance & Installation and Operation Manual X-TMF-SLA5800-MFC-eng Troubleshooting Part Number: 541B027AAG Brooks ® Digital MFC's & MFM's April, 2013 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 55: Section A Essential Instructions

    Section A Essential Instructions Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG April, 2013 ® Brooks Digital MFC's and MFM's Bulgarian Brooks Instrument Brooks Instrument. Brooks Instrument : (1) . (2) Brooks Instrument (PED) 0,5 bar (g) 25 mm 1" ( (PED).
  • Page 56 P ed instalací si p e t te následující instrukce! Spole nost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standard . P ístroje musí být ádn nainstalovány, používány a udržovány tak, aby byl zajišt n jejich nep etržitý provoz v rámci normálních technických specifikací. Musíte dodržovat následující...
  • Page 57 Om kvalitet af signalkabler, kabeltilslutninger og koblinger: Brooks tilbyder kabler af højest kvalitet, som er tilpasset CEE kvalificeringens forskrifter. Hvis man vælger at bruge egne kabler, skal man vælge et kabel som har den nødvendige afskærmning for at sikre 100 % mod udefra kommende støj.
  • Page 58 Lees ze voordat u verder gaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken. De volgende instructies moeten worden toegevoegd aan en geïntegreerd in uw veiligheidsprogramma als u producten van Brooks Instrument installeert, bedient en onderhoudt.
  • Page 59 Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljude erinevate riiklike ja rahvusvaheliste standardite nõuetele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrument'i toodete paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi.
  • Page 60 PED direktiiviä koskevat määräykset löytyvät käyttöoppaan ’’Tekniset tiedot” -luvusta. Käyttöoppaassa kuvatut mittarit ovat 97/23/EC EU-direktiivin mukaisia. Kaikki Brooks Instrumentin virtausmittarit kuuluvat virtausryhmään 1. Laitteet jotka ovat suurempia, kuin 25 mm tai 1 tuuma, ovat PED I, II, III kategorien mukaisia.
  • Page 61 Brooks Instrument et que des personnes qualifiées effectuent le remplacement. Les pièces et procédures non autorisées peuvent porter atteinte au fonctionnement du produit et mettre en péril la sécurité de votre procédé. Les remplacements par des pièces d’apparence similaire peuvent entraîner des incendies, des risques électriques ou un mauvais fonctionnement.
  • Page 62 Bitte zuerst lesen! Brooks Instrument entwickelt, produziert und testet seine Produkte derart, dass sie viele nationale und internationale Standards erfüllen. Nur bei korrektem Einbau sowie richtiger Bedienung und Wartung dieser Produkte ist ein Betrieb unter Einhaltung der Standardvorgaben sichergestellt. Die folgenden Anweisungen müssen eingehalten werden und in Ihr Sicherheitsprogramm integriert werden, wenn Sie Brooks Produkte installieren, bedienen und warten.
  • Page 63 Section A Essential Instructions Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG April, 2013 ® Brooks Digital MFC's and MFM's Greek Brooks Instrument Brooks Instrument. ’ Brooks Instrument. : (1) . (2) Brooks Instrument. (PED) 0,5 bar (g) 25 mm (PED).
  • Page 64 üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál m ködési tartományuknak megfelel en üzemelhessenek. Az alábbi utasításokat be kell tartani, és be kell építeni a munkavédelmi programba a Brooks Instrument termékeinek telepítése, üzemeltetése és karbantartása során.
  • Page 65 Leggerle subito! La Brooks Instrument progetta, fabbrica e collauda i propri prodotti in maniera tale che siano conformi ai vari standard nazionali ed internazionali. Tali apparecchiature devono essere installate, messe in esercizio e tenute in manutenzione in maniera adeguata affinché operino in conformità alle loro normali specifiche di funzionamento.
  • Page 66 P rliecinieties par to, lai pirms instrumenta tehnisk s apkopes b tu likvid ts procesa l nijas spiediens. Ja ir nepieciešams veikt k du da u nomai u, nodrošiniet, lai tiktu izmantotas „Brooks Instrument” nor d t s da as un da u nomai u veiktu kvalific ts person ls. Neat autu da u un proced ru izmantošana var ietekm s ražojuma sniegumu un samazin t procesa droš...
  • Page 67 Jei nuot ki n ra, sukurkite sistemoje darbin sl g . Prieš atlikdami prieži ros darbus b tinai pašalinkite sl g proceso linijoje. Jei reikia pakeisti dalis, užtikrinkite, kad kvalifikuoti darbuotojai naudot „Brooks Instrument“...
  • Page 68 Urz dzenia pomiarowe o wielko ci 25 mm lub 1 cala lub mniejsze podlegaj zaleceniom „Uznanej Praktyki In ynierskiej” (SEP). Europejska dyrektywa dotycz ca kompatybilno ci elektromagnetycznej (EMC) Urz dzenia elektryczne / elektroniczne firmy Brooks Instrument posiadaj ce oznaczenie CE, przesz y pozytywnie testy pod k tem spe niania przez nich wymogów kompatybilno ci elektromagnetycznej (Dyrektywa EMC 2004/108/EC).
  • Page 69 Ler antes de proceder! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização. As instruções seguintes devem ser, durante a instalação, uso e/ou manutenção dos equipamentos da Brooks Instrument, apreendidas e integradas no plano de...
  • Page 70 În m sura în care indica iile c r ii ma inii nu sunt suficient de l muritoare, lua i leg tura cu reprezentantul Brooks Instrument pentru clarificarea problemei.
  • Page 71 Pre íta pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalova , prevádzkova a udržiava , na zabezpe enie ich spo ahlivej a normálnej prevádzky v celom pracovnom rozsahu.
  • Page 72 Najprej preberite jih Brooks Instrument tako konstruira, izdeluje in terstira svoje izdelke, da oni ustrezajo številnim doma im in mednarodnim standardom. Te naprave se morajo ustrezno instalirati, koristiti in vzdrževati, da vsekakor delajo ustrezno normalnom podro ju funkcioniranja. Naslednjih navodil se mora držati in potrebno je vgraditi v program varstva pri delu pri instaliranju, koriš...
  • Page 73 ¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento.
  • Page 74 Läs detta innan du fortsätter ! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls.
  • Page 75 Installation and Operation Manual X-TMF-SLA5800-MFC-eng Part Number: 541B027AAG ® Brooks Digital MFC's & MFM's April, 2013 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 76 BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service and support to back it up. We operate first class repair facilities located around the world to provide rapid response and support.

This manual is also suitable for:

Sla585Sla5853Sla5860Sla5861Sla5863

Table of Contents