kozy heat ROOSEVELT 29 BAK Installation And Operation Manual page 40

Direct vent gas fireplace insert
Table of Contents

Advertisement

Issue
Pilot and burner
extinguish while in
operation
Soot appears on glass
Flame burns blue and lifts
off burner
No reaction to command
40
TROUBLESHOOTING
Cause
No propane in tank
Incorrect glass assembly
installation
Incorrect vent cap installation
Vent cap blockage
Improper pitch on horizontal
venting
Exhaust vent pipe leaking
exhaust gases back into firebox
Improper media placement
Improper venturi setting
Incorrect vent cap installation
Vent cap blockage
Improper venturi setting
Incorrect vent cap installation
Blockage or leakage of the vent
system
Battery back batteries or remote
control batteries low
No communication between
remote control and IFC module
A maximum number of failed
ignitions or flame restorations
has been reached
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Check propane tank. Refill if necessary.
Refer to section 9.1 Glass Assembly on page 23.
Adjust if necessary.
Remove debris if necessary.
¼" (6mm) rise per foot (30cm) is required on horizontal venting
Check for leaks and repair if necessary.
Refer to Section 9.4 on page 25
Venturi air shutter may need to be opened slightly to allow more air into
the gas mix. Refer to section 12.2.1 Burner Venturi on page 35.
Adjust if necessary.
Remove debris if necessary.
Venturi air shutter may need to be opened slightly to allow more air into
the gas mix. Refer to section 12.2.1 Burner Venturi on page 35.
Adjust if necessary.
Check the vent pipes for leaks, and the vent cap for debris. Repair the vent
pipes or remove debris from vent cap, if necessary.
Replace batteries.
Reprogram remote control to IFC module.
Reset IFC module.
Solution