Advertisement

DreamStation
CPAP
CPAP Pro
Auto CPAP
User manual

Advertisement

Table of Contents
loading

Summary of Contents for Philips Respironics DreamStation CPAP

  • Page 1 DreamStation CPAP CPAP Pro Auto CPAP User manual...
  • Page 2: Table Of Contents

    Traveling with the System ..........................24 Cleaning the Device ............................24 Caring for the Filters ............................24 Cleaning the Tubing ..............................25 Service ..................................25 Additional Notices ...............................25 Speci昀椀cations ................................26 Disposal ..................................27 EMC Information ..............................27 Limited Warranty ........................... Back Page © Koninklijke Philips N.V., 2018. All rights reserved.
  • Page 3: Intended Use

    • Use only power cords supplied by Philips Respironics for this device. Use of power cords not supplied by Philips Respironics may cause overheating or damage to the device and may result in increased emissions or decreased immunity of the equipment or system.
  • Page 4: Cautions

    • When DC power is obtained from a vehicle battery, the device should not be used while the vehicle’s engine is running. Damage to the device may occur. • Only use a Philips Respironics DC Power Cord and Battery Adapter Cable. Use of any other system may cause damage to the device. Contraindications When assessing the relative risks and bene昀椀ts of using this equipment, the clinician should understand that this device can deliver...
  • Page 5: Symbols Glossary

    Symbols Glossary The following symbols may appear on the device, power supply and accessories: De昀椀nition Symbol Reference IEC 60878 Operator’s manual; operating instructions ISO 7000-1641 Consult instructions for use. Symbol 5.4.3, ISO 15223-1 AC power (Alternating current) Indicates on the rating plate that the equipment is suitable for IEC 60417-5032 alternating current only;...
  • Page 6: System Contents

    Should you experience trouble with this equipment or require assistance setting up, using, or maintaining the device or accessories, please contact your home care provider. If you need to contact Philips Respironics directly, call the Philips Respironics Customer Service department at 1-800-345-6443 or 1-724-387-4000. You can also use the following address: Respironics, Inc.
  • Page 7: System Overview

    System Overview The DreamStation CPAP is a Continuous Positive Airway Pressure therapy device designed for the treatment of Obstructive Sleep Apnea (OSA). The DreamStation CPAP Pro can also deliver CPAP-check therapy, and the DreamStation Auto CPAP can also deliver CPAP-Check and Auto-CPAP therapy. Your home care provider will choose the appropriate pressure settings for you.
  • Page 8: Installing/Replacing The Air Filters

    Installing/Replacing the Air Filters Caution: A properly installed, undamaged Philips Respironics blue pollen 昀椀lter is required for proper operation. The device uses a reusable blue pollen 昀椀lter that can be rinsed and and a disposable light-blue ultra-昀椀ne 昀椀lter. The reusable blue 昀椀lter screens out normal household dust and pollens, while the light-blue ultra-昀椀ne 昀椀lter provides more complete 昀椀ltration of very 昀椀ne particles.
  • Page 9: Where To Place The Device

    Where to Place the Device Place the device on a 昀椀rm, 昀氀at surface somewhere within easy reach of where you will use it at a level lower than your sleeping position. Make sure the device is away from any heating or cooling equipment (e.g., forced air vents, radiators, air conditioners).
  • Page 10: Connecting The Breathing Circuit

    To use the system, you will need the following accessories in order to assemble the recommended breathing circuit: • Philips Respironics interface (nasal mask or full face mask) with integrated exhalation port, or Philips Respironics interface with a separate exhalation device (such as the Whisper Swivel II) •...
  • Page 11: Navigating The Device Screens

    Starting the Device 1. Ensure power is supplied to the device. The 昀椀rst screen to display will be the Philips Respironics logo, followed by the device model screen, and then the Home screen. Home Screen The 昀椀rst time the device is powered on, a pop-up may prompt you to set the time on the device.
  • Page 12: Menu Navigation (Therapy On) And Optional Humidi昀椀Cation Settings

    Menu Navigation (Therapy ON) and Optional Humidi昀椀cation Settings While the device is delivering therapy, you can adjust Tube Temperature or Humidi昀椀er Settings. Rotate the control dial to choose either setting. Press and rotate the dial to change the setting. Note: If you are using the Humidi昀椀er without the Heated Tube, simply just rotate the control dial to change the Humidi昀椀er setting.
  • Page 13: Menu Navigation (Therapy Off)

    Menu Navigation (Therapy OFF) From the Home screen, you can scroll between the following menus. Only the menus available and enabled on your device will display. My Info Preheat My Provider My Setup My Info: This menu provides summary statistics of your therapy use. Preheat (if available): This function lets you warm up your humidi昀椀er for 30 minutes before starting a therapy session.
  • Page 14 Icon Text Description 90% Pressure This screen displays the nightly value of 90% Pressure for the most recent 1 day Pressure time frame. It also displays the average of these individual nightly values of 90% Pressure over a 7 day and a 30 day time frame. Available on the Auto model. Preheat (if available): Preheat On Screen Preheat Off Screen...
  • Page 15 Icon Text Description VIC90 This Visual Inspection Check screen will display a check code number created VIC90 from information gathered over the most recent 90 day period. This 15 digit number will display as: xxx.xxxx.xxxx.xxxx. Your home care provider may periodically ask you for this information.
  • Page 16 You can choose either (22) for the Philips Respironics 22 mm tubing, (15) for the Philips Respironics 15 mm tubing, or (12) for the optional Philips Respironics 12 mm tubing. When using Heated Tubing, the device will automatically change this setting to the appropriate tubing type (15H) and you will not be able to change it.
  • Page 17: Bluetooth Wireless Technology

    Bluetooth Wireless Technology Your device has Bluetooth wireless technology. which is one method by which you can transfer your therapy device’s data to DreamMapper. DreamMapper is a mobile and web-based system designed to help Obstructive Sleep Apnea (OSA) patients enhance their sleep therapy experience. Pairing your therapy device to your Bluetooth enabled Mobile Device Note: You can only pair your therapy device to one mobile device at any given time.
  • Page 18: Check Mask Fit

    Check Mask Fit The optional check mask 昀椀t feature can be enabled or disabled by your home care provider. This feature allows you to check the 昀椀t of your mask prior to starting therapy. This is done by measuring the amount of leak. Put on your mask assembly.
  • Page 19: Device Alerts

    Device Alerts Device alerts are pop-ups that show up on the UI screen. There are 5 types of alerts described here: • Status: These alerts are just the pop-up screen. • Noti昀椀cation: These alerts consist of the pop-up screen in addition to a blinking Power LED on top of the device. •...
  • Page 20 Alert Icon Type Description Possible Cause Action Noti昀椀cation Reinsert SD card, or SD Card Indicates SD card has SD card was not Removed. or Alert 2 been removed from reinserted into device. click to clear alert. therapy device and not reinserted before the start of the current therapy session.
  • Page 21 If alert continues, contact your provider. The attached Alert 2 Indicates that the Incorrect power Switch to a Philips power supply attached power supply. Respironics does not support supply is not capable DreamStation humidi昀椀cation.
  • Page 22 Alert Icon Type Description Possible Cause Action Automatic Off Status Displayed when therapy The mask has been Put your mask back on, con昀椀rm good 昀椀t, ends due to automatic removed. and turn air昀氀ow on to off function. resume therapy. Noti昀椀cation Blocked airway Inlet blocked.
  • Page 23: Troubleshooting

    Make sure the Tubing type setting (22 or 15) matches the tubing that you are using feels too high or too setting may be (Philips Respironics 22 or 15 mm tubing). low. incorrect. If you are using the Heated Tubing, this setting will be 15H and you cannot change it.
  • Page 24: Accessories

    Why It Happened What To Do Problem I’m having dif昀椀culty The humidi昀椀er setting and tube temperature settings can only be adjusted from the The blower is not adjusting the heated turned on, or the Therapy ON display screen. Con昀椀rm that the blower is turned on, and that the humidi昀椀er setting humidi昀椀er or heated settings are visible on the right side of the screen, then adjust to desired comfort.
  • Page 25 昀椀re hazard. • When adding oxygen at the mask end of the hose, a Philips Respironics Pressure Valve is not required for oxygen 昀氀ow rates of ≤4 liters per minute. However, the reusable and disposable 昀椀lters must be in place on the 昀氀ow generator.
  • Page 26: Traveling With The System

    昀椀lter to rinse away any debris. 4. Shake the 昀椀lter to remove as much water as possible. 5. Allow the 昀椀lter to air dry completely before reinstalling it. If the 昀椀lter is damaged, replace it. (Only Philips Respironics-supplied 昀椀lters should be used as replacement 昀椀lters.) 6.
  • Page 27: Cleaning The Tubing

    The Bluetooth Notice: any use of such marks by Philips Respironics is under license. Other trademarks and trade names are those of their respective owners. The DreamStation Therapy Device is capable of transmitting data between the therapy device and a Notice: mobile device.
  • Page 28: Speci昀椀Cations

    Speci昀椀cations Environmental Operating Temperature: 5° to 35° C (41° to 95° F) Storage Temperature: -20° to 60° C (-4° to 140° F) Relative Humidity (operating & storage): 15 to 95% (non-condensing) Atmospheric Pressure: 101 to 77 kPa (0 - 2286 m / 0 - 7500 ft) Physical Dimensions: 15.7 x 19.3 x 8.4 cm (6.2”...
  • Page 29: Disposal

    Pressure Accuracy Pressure Increments: 4.0 to 20.0 cm H O (in 0.5 cm H O increments) Maximum static pressure accuracy, according to ISO 80601-2-70:2015: Pressure Static Accuracy ± 0.3 cm H 10 cm H Static pressure accuracy has a measurement uncertainty of 3.7% Maximum dynamic pressure variation, according to ISO 80601-2-70:2015: Pressure 10 BPM...
  • Page 30 Guidance and Manufacturer’s Declaration - Electromagnetic Emissions – This device is intended for use in the electromagnetic environment speci昀椀ed below. The user of this device should make sure it is used in such an environment. Electromagnetic Environment - Guidance Emissions Test Compliance Group 1 The device uses RF energy only for its internal function.
  • Page 31: Limited Warranty

    Limited Warranty Respironics, Inc. warrants that the system shall be free from defects of workmanship and materials and will perform in accordance with the product speci昀椀cations for a period of two (2) years from the date of sale by Respironics, Inc. to the dealer.
  • Page 32 1120830 1120830 R10 HM 12/05/2018 EN-DOM...

Table of Contents