Shortly after applying power, the analyzer will display the EMS logo & world start up screen.
It will disappear once and reappear (Figure 8) for approx.15 sec. then switch to the Home sampling
screen (Figure 9). This starts the analyzer warm-up mode and will continue for approximately 5 to
10 minutes, depending on ambient temperature. Once the warm-up is complete, the analyzer will
go into the "ZEROING" mode to set all the gases to zero. Then the gas sample mode will display all
the gas values (Figure 10). 4 Gas units will show CO2, CO, HC, O2 (figure 11) Note: Below the
gas data is a status line where operations and/or errors will be displayed.
Figure 8
Figure 10
Once the analyzer has completed the warm-up, the sample hose can now be connected
Caution: Exhaust gases pass through the gas analyzer and vent through its ex-
haust. Use the analyzer in a well vented area. EMS can supply a venting hose assembly.
Note: Gas analyzers are designed for diagnostics and verification of repairs. The
sample probe should be removed from the tailpipe after taking readings to prolong
Caution: Monitor the clear hose between the filter assembly and the housing. If
moisture appears in the tubing, remove the probe from the tailpipe and disconnect the
sample hose from the analyzer immediately. Use compressed air to remove moisture from
the sample hose. Operate the analzyer without the exhaust sample hose connected until
the moisture is removed. It may be necessary to replace the filters. Once the lines are dry,

Gas Analyzer Operation

and the probe placed in the tailpipe.
analyzer life and save on maintenance costs.
normal operation can continue.
Figure 11
8
Figure 9