Drive Information; Data Readouts - Trane TR150 Programming Manual

Hide thumbs Also See for TR150:
Table of Contents

Advertisement

Parameter Lists

5.1.12 15-** Drive Information

Par. No. #
Parameter description
15-0* Operating Data
15-00
Operating Hours
15-01
Running Hours
15-02
kWh Counter
15-03
Power Up's
15-04
Over Temp's
15-05
Over Volt's
15-06
Reset kWh Counter
15-07
Reset Running Hours Counter
15-3* Alarm Log
15-30
Alarm Log: Error Code
15-4* Drive Identification
15-40
FC Type
15-41
Power Section
15-42
Voltage
15-43
Software Version
15-44
Ordered TypeCode
15-46
Drive Ordering No
15-47
Power Card Ordering No
15-48
LCP Id No
15-49
SW ID Control Card
15-50
SW ID Power Card
15-51
Drive Serial Number
15-53
Power Card Serial Number

5.1.13 16-** Data Readouts

Par. No. #
Parameter description
16-0* General Status
16-00
Control Word
16-01
Reference [Unit]
16-02
Reference [%]
16-03
Status Word
16-05
Main Actual Value [%]
16-09
Custom Readout
16-1* Motor Status
16-10
Power [kW]
16-11
Power [hp]
16-12
Motor Voltage
16-13
Frequency
16-14
Motor current
16-15
Frequency [%]
16-18
Motor Thermal
16-3* Drive Status
16-30
DC Link Voltage
16-34
Heatsink Temp.
16-35
Inverter Thermal
TR150 Programming Guide
Default value
2-set-up
0 h
All set-ups
0 h
All set-ups
0 kWh
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
[0] Do not reset
All set-ups
0 N/A
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
Default value
0 N/A
0 ReferenceFeedbackUnit
0 %
0 N/A
0 %
0 CustomReadoutUnit
0 kW
0 hp
0 V
0 Hz
0 A
0 %
0 %
0 V
0 °C
0 %
BAS-SVP16A-EN - Rev. 2013-09-05
Change
Conver-
during
sion index
operation
TRUE
74
TRUE
74
TRUE
75
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
2-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
Type
Uint32
Uint32
Uint32
Uint32
Uint16
5
Uint16
Uint8
Uint8
Uint8
VisStr[6]
VisStr[20]
VisStr[20]
VisStr[20]
VisStr[40]
VisStr[8]
VisStr[8]
VisStr[21]
VisStr[21]
VisStr[21]
VisStr[10]
VisStr[20]
Type
0
Uint16
-3
Int32
-1
Int16
0
Uint16
-2
Int16
-2
Int32
-3
Uint32
-3
Uint32
-1
Uint32
-1
Uint32
-2
Uint16
-1
Uint16
0
Uint8
0
Uint32
100
Int8
0
Uint8
95
5

Advertisement

Table of Contents
loading

Table of Contents