3.11 Main Menu - Drive Information - Group

15
Parameter group containing frequency converter
information such as operating data, hardware configu-
ration and software versions.
3.11.1 15-0* Operating Data
15-00 Operating hours
Range:
Function:
0 h
[0 - 0x7fffffff.
View how many hours the frequency
*
h]
converter has run. The value is saved
when the frequency converter is turned
off.
15-01 Running Hours
Range:
Function:
0 h
[0 - 0x7fffffff.
View how many hours the motor has run.
*
h]
Reset the counter in 15-07 Reset Running
Hours Counter. The value is saved when the
frequency converter is turned off.
15-02 kWh Counter
Range:
Function:
0 kWh
[0 - 65535
View the output power of the frequency
*
kWh]
converter in kWh as a mean value over 1
hour. Reset the counter in 15-06 Reset kWh
Counter.
15-03 Power Up's
Range:
Function:
0
[0 - 2147483647 ] View the number of times the frequency
*
converter has been powered up.
15-04 Over Temp's
Range:
Function:
0
[0 - 65535 ] View the number of frequency converter
*
temperature faults which have occurred.
15-05 Over Volt's
Range:
Function:
0
[0 - 65535 ] View the number of frequency converter
*
overvoltages which have occurred.
15-06 Reset kWh Counter
Option:
Function:
NOTICE
Pres [OK] to reset.
[0]
Do not reset
*
TR150 Programming Guide
15-06 Reset kWh Counter
Option:
[1]
Reset counter Select [1] Reset and press [OK] to reset the
15-07 Reset Running Hours Counter
Option:
[0]
Do not reset
*
[1]
Reset counter Select [1] Reset counter and press [OK] to
3.11.2 15-3* Alarm Log
Parameters in this group are array parameters, where up to
10 fault logs can be viewed. [0] is the most recent logged
data, and [9] the oldest. Error codes, values, and time
stamp can be viewed for all logged data.
15-30 Alarm Log: Error Code
Range:
0
[0 - 255 ] View the error code and look up its meaning in .
*
15-31 InternalFaultReason
Range:
0
[-32767 -
*
32767 ]
3.11.3 15-4* Drive Identification
Parameters containing read only information about the
hardware and software configuration of the frequency
converter.
15-40 FC Type
Range:
0
[0 - 0 ] View the FC type code. The read-out is identical to
*
15-41 Power Section
Range:
0
[0 - 0 ] View the FC type code. The read-out is identical to
*
15-42 Voltage
Range:
0
[0 - 0 ] View the FC type code. The read-out is identical to
*
BAS-SVP16A-EN - Rev. 2013-09-05
Function:
kWh counter to zero (see 15-02 kWh
Counter).
Function:
reset Running Hours counter (15-01 Running
Hours) to zero (see also 15-01 Running
Hours).
Function:
Function:
View a description of the error. This
parameter is used in combination with alarm
38 Internal Fault.
Function:
the frequency converter series power field of the
type code definition, characters 1-6.
Function:
the frequency converter series power field of the
type code definition, characters 7-10.
Function:
the frequency converter series power field of the
type code definition, characters 11-12.
3
3