Installation Specification
It is the responsibility of the installer to follow CAME Entrotec's installation and cable specification
as well as ALL relevant wiring regulations. Failure to comply with CAME Entrotec's installation and
cable specification may result in erratic operation of equipment and could invalidate any warranty.
Installations must comply with the following applicable standards:
BS 7671: Requirements for electrical installations. IET Wiring Regulations 18th Edition.
The Electricity at Work Regulations 1989
ANSI/TIA-568.0-D: Generic Telecommunications Cabling for Customer Premises.
ANSI/TIA-568.1-D: Commercial Building Telecommunications Cabling Standard.
IET Wiring Regulations 18th Edition: Regulation 444 (MEASURES AGAINST
ELECTROMAGNETIC DISTURBANCES) imposes requirements for segregation of circuits.
IET Wiring Regulations 18th Edition: Regulation 528 (PROXIMITY TO WIRING SYSTEMS TO
OTHER SERVICES) imposes requirements for segregation of door entry / access control circuits
(Band I), 230VAC mains circuits (Band II) and other higher voltage circuits.
IET Wiring Regulations 18th Edition: Regulations 541 and 542 impose requirements for earthing
and bonding conductors. Ensure ALL metalwork is bonded to the buildings earth, this includes call
panels, exit switches, cabinets and metal conduit. Ring terminals and earth points are provided on
call panels and cabinets to terminate earth cables, ensure these connections are made.
� WARNING - ISOLATION OF ELECTRICAL EQUIPMENT
In compliance with The Electricity at Work Regulations 1989, electrical equipment should be
made dead to prevent danger while work is carried out on or near that equipment. No person
shall be engaged in any work activity on or so near any live conductor.
Warranty and Support
CAME Entrotec systems are renowned for their reliability and have a 2-year warranty on all CAME
Entrotec manufactured products as standard. This warranty does not cover water damage,
vandalism, mains electrical faults, lightning strikes, damage caused by miswiring or cable faults.
CAME Entrotec offer complimentary training courses and telephone support: