Cable Specification; Typical Configuration - CAME ENTROTEC PRO-DC4 Installation & Setup Manual

Table of Contents

Advertisement

Cable Specification

1 Cable Specification
The cabling system is based on Unshielded Twisted Pair Category 5e (Cat5e) or Category 6
(Cat6). The cable must be annealed pure copper, meeting or exceeding the requirements
defined in the standard ANSI/TIA 568 C.2.
Failure to comply with this cable specification may result in erratic operation of equipment.
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
A
Door controller to each call
panel:
B
Lock Relay to locks:
C
Lock Relay to exit switch:
D
Lock Relay to fire switch:
1.1

Typical Configuration

NOTE
For setup of the Call Panel refer to the PRO-DP* Installation Guide.
4
Cable
2x Cat5e or Cat6.
2x 1.5mm² multi-stranded flex or singles (route through
any exit/fire switch or break glass for fail safe operation).
1 Pair UTP (2 cores), Cat5e or Cat6.
1 Pair UTP (2 cores), Cat5e or Cat6.