Table of Contents

Advertisement

User Guide

Advertisement

Table of Contents
loading

Summary of Contents for Schiller CARDIOVIT FT-1

  • Page 1 User Guide...
  • Page 2 The SCHILLER sales and service centre network is world-wide. Contact your nearest SCHILLER subsidiary to obtain the address of your local distributor. In case of difficulty, a complete list of all distributors and subsidiaries is provided on our internet site: www.schiller.ch...
  • Page 3: Table Of Contents

    1.11 Safety Symbols and Pictograms ........11 1.11.1 Symbols used in this document ............11 1.11.2 Symbols used on the device ............12 Introduction ..........13 Main components of the CARDIOVIT FT-1 ....... 13 2.1.1 Standard................... 14 2.1.2 Options..................... 14 Connections................
  • Page 4 CARDIOVIT FT-1 Placing the electrodes ......29 Basics .................. 29 Electrode Identification and Colour Code ......30 Standard 10-lead resting ECG ........... 31 4.3.1 Electrode placement for standard leads .......... 31 Balanced................32 Paediatric................33 Right precordials (C3r-C6r)..........34 Standard with C4r ............... 35 Left posterior C7-C9 ............
  • Page 5 10.1 Transmission Options............87 10.1.1 Automatic transmission ..............88 10.1.2 Manual transmission ................ 88 10.1.3 PDF export ..................89 10.1.4 Schiller Link..................90 10.1.5 Receiving data from SEMA .............. 91 10.1.6 Failed data transmission ..............91 10.2 FT-1 streaming..............92 Maintenance ..........
  • Page 6 CARDIOVIT FT-1 Trouble shooting ........100 12.1 Possible problems............100 12.2 Preventing electromagnetic interferences ..... 102 12.2.1 Measures to prevent electromagnetic interferences ...... 103 12.3 Accessories and disposables ......... 104 Technical data ........105 13.1 Device ................105 13.2 ECG ..................107 13.3...
  • Page 7: Safety Notes

     The CARDIOVIT FT-1 is a 12-channel ECG unit used for the recording, analysis, viewing, storage and transmission of ECGs.  The CARDIOVIT FT-1 is designed for indoor use and can be used for all patients of both sexes, all ethnicities and all ages.
  • Page 8: Safety-Conscious Operation

    The device must be serviced before reusing.  Only connect the original SCHILLER patient cable to the patient socket.  If the patient cable should become defective after defibrillation, an electrode becomes displaced, or an electrode resistance is too high, a lead-off indication is displayed in the upper right part of the screen.
  • Page 9: Operation With Other Devices

     There is no danger when using this device simultaneously with electrical stimulation equipment.  If the device is part of a medical system, only the original SCHILLER patient cable must be used with, and connected to, the CARDIOVIT FT-1.
  • Page 10: Terms Of Warranty

    SCHILLER makes no warranty of merchantability or fitness for a particular purpose with respect to the product or parts thereof. SCHILLER assumes no liability for the loss of data saved on the computer or on the device. The owner is solely responsible for the data backup.
  • Page 11: Safety Symbols And Pictograms

    Safety Notes CARDIOVIT FT-1 User Guide Safety Symbols and Pictograms 1.11 1.11 Safety Symbols and Pictograms 1.11.1 Symbols used in this document The safety level is classified according to ISO 3864-2. The following overview shows the safety symbols and pictograms used in this manual.
  • Page 12: Symbols Used On The Device

    The CARDIOVIT FT-1 radiates high-frequency electromagnetic energy and can dis- turb other devices if not installed and operated in accordance with the user guide. CARDIOVIT FT-1 However, there is no guarantee that no interference can occur in certain installations. If the CARDIOVIT FT-1 causes interferences, these can be de- termined by switching the device off/on or by transmitting/not transmitting ECG data.
  • Page 13: Introduction

    Main components of the CARDIOVIT FT-1 2 Introduction The SCHILLER CARDIOVIT FT-1 is a 12-channel ECG unit designed to record, display, and measure resting ECGs. The multi-touch screen allows easy and intuitive operation to efficiently enter patient data, record ECGs and adjust device settings.
  • Page 14: Standard

    Introduction CARDIOVIT FT-1 Connections 2.1.1 Standard • Pacemaker detection • Manual rhythm printout in real time (leads, speed and amplitude can be changed) • Auto mode recording (10 seconds) with user-defined layout • Rhythm • Measurements • Full disclosure of all 12 channels •...
  • Page 15: Display

    Introduction CARDIOVIT FT-1 User Guide Display Display The display will vary according to the task being carried out. In all screens, however, the top, bottom and right areas always display the same category of information. Example for a typical patient data view:...
  • Page 16: Multi-Touch Screen Operation

    Introduction CARDIOVIT FT-1 Multi-touch screen operation Multi-touch screen operation The touch-sensitive areas of the screen are located as follows: Patient ID / Visit ID Hugh Brian I 53 years I Male Visit ID Visit ID Patient ID Patient ID  Enter patient and...
  • Page 17 Introduction CARDIOVIT FT-1 User Guide Multi-touch screen operation Record ECG  Prepare ECG recording Patient ID I Visit ID Hugh Brian I 53 years I Male – Determine electrode positions and apply Standard 12-lead electrodes – Check the signal quality –...
  • Page 18: Connection Panel

    CARDIOVIT FT-1 Connection panel Connection panel  All externally connected hardware must be approved by SCHILLER. Connection of any hardware not approved by SCHILLER is at the owner‘s risk. Moreover, the unit's warranty may become invalid. 2.5.1 Back panel (1) Power input 15 VDC (2) Potential equalisation stud.
  • Page 19: Operation

    • Do not allow the unit to come into contact with acidic vapours or liquids. • The CARDIOVIT FT-1 must not be placed in the vicinity of X-ray or diathermy units, large transformers or electric motors.
  • Page 20: Switching On / Off

    Login and Logout / Emergency ECG If Access control is activated, the following dialogues are displayed: Login  Enter the password and press “Login” to log in. In addition, for access control modes “Local” or “Schiller Server”, a user name is required. Password: Emergency ECG...
  • Page 21: Power Supply

    Operation CARDIOVIT FT-1 User Guide Power supply Power supply 3.3.1 Mains and battery indicators The unit can either be operated from the mains supply or from the built-in rechargeable battery. Battery charging is indicated by the LED below the battery symbol.
  • Page 22: System And Ecg Settings

    Operation CARDIOVIT FT-1 System and ECG settings System and ECG settings • The system settings (time, date, device ID etc.) and other general settings are de- scribed on Page • Resting ECG settings (auto format, user defined leads, print options, interpretation, rhythm lead definition, etc.) are described on...
  • Page 23: Changing The Printing Paper

    • Certain glues can react with the paper. Therefore, do not use glue to attach the printout onto a mounting sheet. SCHILLER can only guarantee perfect printouts when original SCHILLER chart paper or chart paper of the same quality is used.
  • Page 24: Patient / Recording Data

    Operation CARDIOVIT FT-1 Patient / recording data Patient / recording data In the patient data screen, new patients can be entered and previously stored patient data can be edited. If a recording is performed without having entered a patient or visit ID, a UUID is generated instead of a patient ID, "Emergency ECG"...
  • Page 25 Operation CARDIOVIT FT-1 User Guide Patient / recording data Patient data - left entry fields Patient ID Enter the patient's identification number. Last name Enter patient's name (maximum 50 characters). First name Enter patient's first name (maximum 50 characters). Date of birth Enter the patient‘s date of birth in the format dd-mm-yyyy or yyyy.mm.dd.
  • Page 26 Operation CARDIOVIT FT-1 Patient / recording data Recording data - left side Room Examination room Medication Digitalis Indication Reason for medication Recording data - right side Referring physician Referring physician Attending physician Attending physician Remark Remarks about the patient/recording Deleting entered patient data.
  • Page 27: Patient Data Query (Pdq)

    Operation CARDIOVIT FT-1 User Guide Patient / recording data 3.6.1 Patient data query (PDQ) When the unit is connected to SEMA or another hospital patient database (via network or WLAN), patient data can be filled in automatically when the Patient ID or Visit ID is entered.
  • Page 28: Barcode Reader

    Keyboard > External keyboard layout. A barcode reader can be attached to the USB port on the back panel to read the Patient ID / Visit ID. SCHILLER has tested the following barcode reader:  Symbol Model LS 2208, from Symbol Tech N.Y.
  • Page 29: Placing The Electrodes

    A minimal resistance between skin and electrode is required to obtain the best ECG signal and ensure the highest quality ECG recording. Therefore, please note the following points: Only use electrodes that are recommended by Schiller AG (see accessories) Before using disposable electrodes, check that the expiration date has not yet passed.
  • Page 30: Electrode Identification And Colour Code

    Placing the electrodes CARDIOVIT FT-1 Electrode Identification and Colour Code Electrode Identification and Colour Code The electrode colour codes in the following sections correspond to Code 1 (IEC) for the graphics and to Code 2 (AHA) in the tables IEC label...
  • Page 31: Standard 10-Lead Resting Ecg

    Placing the electrodes CARDIOVIT FT-1 User Guide Standard 10-lead resting ECG Standard 10-lead resting ECG C1 Red C2 Yellow C3 Green C4 Brown C5 Black C6 Violet R Red L Yellow N Black F Green 4.3.1 Electrode placement for standard leads...
  • Page 32: Balanced

    Placing the electrodes CARDIOVIT FT-1 Balanced Balanced C7 (C4 brown) C8 (C5 black) C9 (C6 purple) C4r (C3 green) C3r (C2 yellow) C1 Red L Yellow R Red F Green N Black Balanced, 10-wire cable IEC label AHA label Electrode placement...
  • Page 33: Paediatric

    Placing the electrodes CARDIOVIT FT-1 User Guide Paediatric Paediatric C2 Yellow C7 Red C3r Green C5 Black C6 Purple C4r Brown R Red L Yellow N Black F Green IEC label AHA label Electrode placement C4r white / brown V4 brown / blue ...
  • Page 34: Right Precordials (C3R-C6R)

    Placing the electrodes CARDIOVIT FT-1 Right precordials (C3r-C6r) Right precordials (C3r-C6r) Since the treatment of an infarction might depend on the influence of the right ventricle, it is suggested to perform additional recordings with right precordial leads in the case of an acute infarction of the right ventricle's inferior wall (Circulation 2007).
  • Page 35: Standard With C4R

    Placing the electrodes CARDIOVIT FT-1 User Guide Standard with C4r Standard with C4r ACC/AHA guidelines recommend examining patients suffering from a myocardial infarction with inferior ST elevation for possible RV ischaemia or RV infarction; this examination should be performed with a right precordial C4r lead.
  • Page 36: Left Posterior C7-C9

    Placing the electrodes CARDIOVIT FT-1 Left posterior C7-C9 Left posterior C7-C9 If an acute coronary occlusion is strongly suspected, it is recommended to also register posterior chest wall leads (C7–C9) C4 Brown C7 (C1 Red) C5 Black C8 (C2 Yellow)
  • Page 37: Nehb Leads

    Placing the electrodes CARDIOVIT FT-1 User Guide Nehb leads Nehb leads The Nehb leads are bipolar chest leads. They are of special interest for the diagnosis of changes in the posterior ventricle wall. Three leads are arranged in the form of a triangle, also called the “small cardiac triangle”.
  • Page 38: Skin/Electrode Resistance

    Placing the electrodes CARDIOVIT FT-1 4.10 Skin/Electrode Resistance 4.10 Skin/Electrode Resistance 4.10.1 Electrode and patient cable check The electrode check is part of step 2 before the start of an ECG recording. The following is checked and displayed: • Excessive noise (signal noise too high) –...
  • Page 39: Lead Sequence/Lead View

    Placing the electrodes CARDIOVIT FT-1 User Guide Lead sequence/lead view 4.11 4.11 Lead sequence/lead view 4.11.1 Setting Standard or Cabrera lead sequence  The lead sequence is defined in the settings. (Menu > Settings > ECG > Leads & cable).
  • Page 40: Resting Ecg

     Do not operate the unit if the earth connection is suspect or if the mains lead is damaged or suspected of being damaged.  If an external electronic device (e.g. a PC) is connected to the CARDIOVIT FT-1, use the potential equalisation stud for earth protection.
  • Page 41: Resting Ecg - Procedural Flow Diagram

    Prepare the patient, connect the retrieving patient data electrodes and switch on the device • Patient master data from a network (worklist, PDQ or Schiller Link) • Recording data • Hookup  Apply electrodes  Check the signal • Recorder ...
  • Page 42: Printing, Saving And Transferring Automatically

    Resting ECG CARDIOVIT FT-1 Resting ECG - procedural flow diagram 5.1.1 Printing, saving and transferring automatically Menu > Settings > General > Workflow Activate Print after acquisition, Transmit after acquisition and Delete after transmission to automatically print and transmit a saved recording or to delete recordings after transmission.
  • Page 43: Automatic Resting Ecg Recording

    Resting ECG CARDIOVIT FT-1 User Guide Automatic resting ECG recording Automatic resting ECG recording To take an automatic ECG recording, press the Auto key. After approx. 10 seconds, the recording is analysed and the result displayed. The recording can be checked and saved and further printouts can be obtained in different formats.
  • Page 44: Etm Sport

    Resting ECG CARDIOVIT FT-1 Automatic resting ECG recording 5.2.1 ETM Sport When ETM Sport interpretation is selected before the start of a recording, the additional criteria for an athlete's ECG are analysed and displayed. 4d2e58d7-45dc-4cf8-a39e-8d78a8def19c Emergency 20171125153857 Abnormal ECG in athletes...
  • Page 45: Automatic Printout

    Resting ECG CARDIOVIT FT-1 User Guide Automatic resting ECG recording 5.2.2 Automatic printout The printout gives the following: • Heart rate • Patient ID or Visit ID • Time and date • Speed • Sensitivity • Filter • Device ID •...
  • Page 46: Manual Rhythm Printout

    Resting ECG CARDIOVIT FT-1 Manual rhythm printout Manual rhythm printout Use this function to print a real-time ECG. The print parameters such as lead sequence, print speed and sensitivity can be changed by the user during the printout. The real-time ECG is not saved. The chosen settings only apply to the printout.
  • Page 47: Rhythm Recording

    Resting ECG CARDIOVIT FT-1 User Guide Rhythm recording Rhythm recording Press Rhythm to perform a rhythm recording. Select the recording duration in the dialogue that pops up. If a recording is cancelled after more than 10 seconds, it can still be stored. The recording can be checked and saved and further printouts can be obtained in different formats.
  • Page 48: Automatic Printout

    Resting ECG CARDIOVIT FT-1 Rhythm recording 5.4.1 Automatic printout The printout gives the following: • Heart rate • Patient ID or Visit ID • Time and date • Speed • Sensitivity • Filter • Device ID • Serial number • Software version •...
  • Page 49: Changing The Ecg Preview Layout

    Resting ECG CARDIOVIT FT-1 User Guide Changing the ECG preview layout Changing the ECG preview layout The ECG preview is optimised for 2 columns with 6 leads each, or for 3 columns with 4 leads each. The amplitude and speed can be set to 5, 10 or 20 mm/mV, and to 12.5, 25 or 50 mm/s.
  • Page 50: Myogram Filter

    Resting ECG CARDIOVIT FT-1 Changing the ECG preview layout 5.5.2 Myogram filter The myogram filter suppresses disturbances caused by strong muscle tremor. In Menu > Settings > ECG > Filters & formulas, the myogram filter is defined. LP 40Hz, AC 50Hz In the information field, LP 25 Hz, LP 40 Hz or LP 150 Hz is displayed.
  • Page 51: Ecg Settings

    Resting ECG CARDIOVIT FT-1 User Guide ECG settings ECG settings When pressing the Menu key , the option Settings is displayed. The following table gives an overview of all the settings concerning the ECG acquisition: Main menu Patient cable Leads & cable Recorder Filters &...
  • Page 52: Filters & Formulas

    Resting ECG CARDIOVIT FT-1 ECG settings 5.6.2 Filters & formulas Menu Parameter Description / selection Notch filter Off/ AC 50/AC 60 Hz Myogram filter Off = 250 Hz/LP25/LP40/LP150 Hz Filters & formulas Default QTc calculation Bazett, Fridericia, Framingham, Hodges Page 52...
  • Page 53: Views & Layouts

    Resting ECG CARDIOVIT FT-1 User Guide ECG settings 5.6.3 Views & layouts In this menu, the views and layouts for the Preview, RECG review and Resting rhythms are defined. RECG review Preview Rhythm ECG Preview Menu Parameter Description Preview view order...
  • Page 54 Resting ECG CARDIOVIT FT-1 ECG settings RECG review These settings apply to current resting ECG recordings and recordings from the memory. Therefore, saved ECGs can be displayed with different settings at any time. RECG review Preview Rhythm ECG Menu Parameter...
  • Page 55 Resting ECG CARDIOVIT FT-1 User Guide ECG settings Rhythm ECG These settings apply to current resting rhythm recordings and recordings from the memory. Therefore, saved ECGs can be displayed with different settings at any time. R-ECG review Preview Rhythm ECG...
  • Page 56: Additional Leads

    Resting ECG CARDIOVIT FT-1 ECG settings 5.6.4 Additional leads Default leads per lead configuration These settings apply to the current resting rhythm recording, recordings from the memory, and the printout. Therefore, saved ECGs can be displayed or printed with different settings at any time.
  • Page 57: Reports

    Resting ECG CARDIOVIT FT-1 User Guide ECG settings 5.6.7 Reports In this menu, the Print layout is defined. General Parameter Description Sequential or Simultaneous. When Sequential is selected, the individual lead groups show consecutive time segments (applies to the printout). When Simultane-...
  • Page 58 Resting ECG CARDIOVIT FT-1 ECG settings Resting ECG These settings apply to current resting ECG recordings and recordings from the memory. Therefore, saved ECGs can be printed with different settings at any time • The order listed below can vary.
  • Page 59 Resting ECG CARDIOVIT FT-1 User Guide ECG settings 12 lead 12 lead (PDF) 9 lead 9 lead (PDF) Printout formats highlighted in Remove Patient data green are printed. Rhythm 2x6, 25 mm/s, 1 page Remove Averages 4x3+1, 50/25 mm/s, 1 page...
  • Page 60 Resting ECG CARDIOVIT FT-1 ECG settings Rhythm ECG These settings apply to current resting rhythm recordings, resting rhythm recordings from the memory (Internal, display and printout), as well as PDF. Therefore, saved resting rhythm ECGs can be printed with different settings at any time.
  • Page 61: Culprit Coronary Artery Algorithm

    Culprit Coronary Artery Algorithm CARDIOVIT FT-1 User Guide Introduction 6 Culprit Coronary Artery Algorithm Introduction The Culprit Coronary Artery Algorithm developed by Professor Hein Wellens is designed to determine the size of the cardiac area at risk by localising the occlusion...
  • Page 62: Culprit Artery Algorithm Decision Overview

    Culprit Coronary Artery Algorithm CARDIOVIT FT-1 Introduction 6.1.1 Culprit Artery Algorithm Decision Overview Prior Bypass/ PCI centre Stent? PCI = Percutaneous Coronary Intervention QRS width  limit? PCI centre ST Score < lower Transport to nearest hospital limit? ST Score >= lower limit...
  • Page 63: Starting The Ccaa Analysis

    Culprit Coronary Artery Algorithm CARDIOVIT FT-1 User Guide Introduction 6.1.2 Starting the CCAA analysis When CCAA analysis is set, the following applies: • The lead setting is automatically set to Right Precordial (V4r). Ensure that the C4 electrode is placed in the C4r (precordial) position.
  • Page 64: Ccaa Information On Print Preview/Printout

    Culprit Coronary Artery Algorithm CARDIOVIT FT-1 Introduction 6.1.3 CCAA information on print preview/printout Information on LAD (left anterior descending)  For men under the age of 40 showing early repolarisation in the anterior leads, false LAD diagnoses may occur. The following CCAA information is given on the print preview/printout: Manual entry before the start of the recording: –...
  • Page 65: Memory

    User Guide Editing the memory 7 Memory Recordings can be stored locally and transmitted automatically to Schiller Link or SEMA. Recordings stored in the memory can be viewed, printed, transmitted or deleted at any time. Approx. 350 resting ECGs and 100 resting rhythms can be stored on the CARDIOVIT FT-1.
  • Page 66: Opening The Print Preview From The Memory And Printing A Recording

    Memory CARDIOVIT FT-1 Editing the memory 7.1.1 Opening the print preview from the memory and printing a recording If the recording cannot be printed (e.g. no paper), the printout can be generated again by pressing the icon (1) Print jobs in the status bar at the top.
  • Page 67: Transmitting And Deleting Stored Recordings

    Memory CARDIOVIT FT-1 User Guide Editing the memory 7.1.2 Transmitting and deleting stored recordings Depending on the settings in Menu > Settings > General > Workflow, the recording is transmitted and deleted automatically as soon as it has been recorded. If automatic transmission is not activated, recordings can be transmitted as follows.
  • Page 68: Worklist (Option)

    The worklist is defined directly from the Hospital information system (HIS) (e.g. SEMA or GDT) and after the recording has been made by the CARDIOVIT FT-1, the recordings are sent back to the HIS for analysis, examination and storage.
  • Page 69: Receiving A Worklist

    Worklist (Option) CARDIOVIT FT-1 User Guide Receiving a worklist Receiving a worklist To open the worklist proceed as follows: Press Menu > Worklist. Sort recordings Select a recording Search recording Search for PID, Visit ID, first name or last name...
  • Page 70: Taking A Worklist Recording

    Worklist (Option) CARDIOVIT FT-1 Receiving a worklist 8.2.1 Taking a Worklist Recording • This procedure corresponds with the worklist mode “Record from worklist”, see setting Section 9.5 General, page 84, workflow. • Patient data provided by the HIS cannot be edited (except for height and weight).
  • Page 71: Performing A Recording From Work Order Details

    Worklist (Option) CARDIOVIT FT-1 User Guide Receiving a worklist 8.2.2 Performing a recording from work order details • This procedure corresponds with the worklist mode “Record from work order de- tails”, see setting Section 9.5 General, page 84, workflow. • Patient data provided by the HIS cannot be edited (except for height and weight).
  • Page 72: Sending Worklist Recordings To The His

    Worklist (Option) CARDIOVIT FT-1 Receiving a worklist 8.2.3 Sending worklist recordings to the HIS • It is possible to automatically send performed worklist recordings; alternatively, you can have the unit prompt you to manually send worklist items. This is defined in system settings (Menu >...
  • Page 73: General And System Settings

    General and system settings CARDIOVIT FT-1 User Guide System settings 9 General and system settings System settings When pressing the Menu key, the options Settings and Memory are displayed. The following table gives an overview of all the settings available.
  • Page 74 General and system settings CARDIOVIT FT-1 System settings Menu Settings Sub-menu • Info • Power management • Station • Update General • Manage licenses (Page 84) • Mandatory fields • Workflow • Access control • Printer Page 74...
  • Page 75: Saving And Restoring Settings

    General and system settings CARDIOVIT FT-1 User Guide System settings 9.1.1 Saving and restoring settings The settings are saved automatically. Import settings Select Import and Import target USB and enter the desired file name to load the stored settings (e.g. default settings) from the USB to the device.
  • Page 76: Ecg

    General and system settings CARDIOVIT FT-1 The default settings are printed bold 9.2.1 Leads & cable Menu Parameter Description / selection Patient cable IEC or AHA Leads & cable Lead sequence Standard or Cabrera • Standard 12-lead • Paediatric • Right precordials Default lead config.
  • Page 77: Views & Layouts

    General and system settings CARDIOVIT FT-1 User Guide 9.2.3 Views & layouts In this menu, the views and layouts for the Preview, RECG review and Resting rhythms are defined. Preview RECG review Rhythm ECG Preview Menu Parameter Description Preview view order...
  • Page 78: Additional Leads

    General and system settings CARDIOVIT FT-1 9.2.4 Additional leads Default leads per lead configuration These settings apply to the current resting rhythm recording, recordings from the memory, and the printout. Therefore, saved ECGs can be displayed or printed with different settings at any time.
  • Page 79: Reports

    General and system settings CARDIOVIT FT-1 User Guide 9.2.7 Reports In this menu, the Print layout is defined. General Parameter Description Sequential or Simultaneous. When Sequential is selected, the individual lead groups show consecutive time segments (applies to the printout). When Simultane-...
  • Page 80 General and system settings CARDIOVIT FT-1 Resting ECG These settings apply to current resting ECG recordings and recordings from the memory. Therefore, saved ECGs can be printed with different settings at any time • The order listed below can vary.
  • Page 81 General and system settings CARDIOVIT FT-1 User Guide Rhythm ECG These settings apply to current resting rhythm recordings, resting rhythm recordings from the memory (Internal, display and printout), as well as PDF. Therefore, saved resting rhythm ECGs can be printed with different settings at any time.
  • Page 82: Connectivity

    General and system settings CARDIOVIT FT-1 Connectivity Connectivity Menu Parameter Description / selection None – No input field displayed EMR integration Schiller Link (EMR = electronic medical re- – Device ID is displayed cord system) Schiller Server – Host, port, user and password input fields are displayed. (See fol-...
  • Page 83: Regional Settings

    General and system settings CARDIOVIT FT-1 User Guide Regional settings Menu Parameter Description / selection Authentication protocol Select the authentication protocol: PEAP, EAP-TLS or EPA-TTLS User Definition of the user name Password Definition of the password WLAN security Download the certificate via USB port of the device when EAP-TLS is...
  • Page 84: General

    Network host name Host name of the device (e.g. ft1) displayed in the network. Update software The check is performed on the Schiller update server. Therefore, an Check Schiller update server Ethernet/WLAN connection is required, including the necessary net- Update...
  • Page 85 General and system settings CARDIOVIT FT-1 User Guide General Menu Parameter Description / selection Transmit after acquisition ECG data is transmitted after acquisition and storage of the recording Yes, No. After saving, the PDF is automatically exported to the USB...
  • Page 86 Selecting the privileges: Privileges Adjust system settings; Analyse recordings (from memory); Create re- cordings. This requires a working EMR connection and Schiller Server adminis- Schiller Server trator rights. Access control is defined on the Schiller Server. Automatic logout Automatic logout enabled...
  • Page 87: 10 Transmission - Overview

     Security of the network is the sole responsibility of the network operator.  SCHILLER AG takes no responsibility for the configuration of Windows.  In order to guarantee the security of the network, Schiller AG recommends the following: – isolating the FT-1 network from other networks –...
  • Page 88: Automatic Transmission

    If Wifi is activated, the following symbols are displayed • Green symbol: connected to the Wifi network and the SCHILLER Server. • Black Symbol: connected to the network but no connection to the SCHILLER Server • Signal strength is displayed with bars.
  • Page 89: Pdf Export

    Transmission - Overview CARDIOVIT FT-1 User Guide Transmission Options 10.1 10.1.3 PDF export Data integrity  When exporting patient data to a memory stick, the responsible user needs to protect the data with appropriate security measures: – Make sure that only authorised people have access to the memory stick.
  • Page 90: Schiller Link

    Schiller Link Schiller Link is a PC application/service which communicates between the EMR sys- tem and the FT-1.  To activate this communication, set Schiller Link in the menu Connectivity > EMR integration (see page 82).  Integration in the network is automatic, provided the FT-1 is part of the same...
  • Page 91: Receiving Data From Sema

    Patient data can be received from a Schiller SEMA server and automatically entered on the CARDIOVIT FT-1. This is called patient data query (PDQ). To do this, the Patient or Visit ID is entered in the patient data screen manually or via a barcode...
  • Page 92: Ft-1 Streaming

    Transmission - Overview CARDIOVIT FT-1 10.2 FT-1 streaming 10.2 FT-1 streaming As soon as the switched on FT-1 is connected to a PC via the USB interface type B, the device indicates "Ready for streaming". As soon as a recording is started with the CS-104 application on the PC, the FT-1 indicates "Streaming.."...
  • Page 93: 11 Maintenance

     No kinks, abrasion or wear in any cable assembly.  Input/output connectors not damaged. In addition to the visual inspection, switch on the CARDIOVIT FT-1, toggle through the menu and check some functions randomly. In this way, you can check that: •...
  • Page 94: Cleaning The Casing And Cables

    • Confirm that all connectors engage securely. The casing of the CARDIOVIT FT-1 and the cable assemblies can be cleaned with a cloth slightly moistened (not wet) on the surface only. If necessary, a domestic non- caustic cleaner or a 50 % alcohol solution can be used to remove grease stains and finger prints.
  • Page 95: Cleaning The Cable Assembly

    Maintenance CARDIOVIT FT-1 User Guide Cleaning the casing and cables 11.2 11.2.1 Cleaning the cable assembly Before cleaning, inspect the cable for damage. Gently bend and flex all parts of the cable. Inspect for splits in the sheathing, damage or extreme wear, exposed wires or bent connectors.
  • Page 96: Disinfection

    Maintenance CARDIOVIT FT-1 11.3 Disinfection 11.3 Disinfection Disinfection removes certain bacteria and viruses. Please refer to the manufacturer's information. Use commercially available disinfectants intended for clinics, hospitals and medical practices. Disinfect the units in the same way as described for cleaning the units (previous page).
  • Page 97: Battery

    Maintenance CARDIOVIT FT-1 User Guide Battery 11.5 11.5 Battery • No maintenance is required for the lithium-ion polymer batteries. • Replace the battery approx. every 4 years (depending on the application) when the battery running time falls substantially under one hour.
  • Page 98: Inspection Report

    Maintenance CARDIOVIT FT-1 11.6 Inspection report 11.6 Inspection report  The user guide, especially chapter 11, must be read before the inspection.  Recommended inspection interval: Every 6 months Serial no.: ________________ Test Results Date • Casing not damaged Visual inspection 11.1...
  • Page 99: Lifed-Item Replacement Every 3 - 5 Years

    11.6 11.6.1 Lifed-item replacement every 3 - 5 years Inspection Results Replacement Internal battery  Replace internal battery if opera- • Unit sent to SCHILLER service tion falls substantially under one centre for accumulator replace-     ...
  • Page 100: 12 Trouble Shooting

    • Old paper inserted.  Ensure that new SCHILLER paper is inserted.  Note that the CARDIOVIT FT-1 thermal paper is heat- and light- sensitive. If it is not stored in its original seal, stored in high temper- atures or is simply old, print quality can deteriorate.
  • Page 101  Press and hold the On/Off button for 10 seconds to force the device is blocked to switch off. Reconnect mains and switch on.  If the problem persists, call your local SCHILLER representative. Multi-touch screen • Excessive EMC interferences responds ...
  • Page 102: Preventing Electromagnetic Interferences

    Trouble shooting CARDIOVIT FT-1 12.2 Preventing electromagnetic interferences 12.2 Preventing electromagnetic interferences The user can help avoid electromagnetic disturbances by keeping the minimum distance between portable and mobile HF telecommunication devices (transmitters) and the FT-1. The distance depends on the output performance of the communication device, as indicated below.
  • Page 103: Measures To Prevent Electromagnetic Interferences

    Trouble shooting CARDIOVIT FT-1 User Guide Preventing electromagnetic interferences 12.2 12.2.1 Measures to prevent electromagnetic interferences The user can take the following measures to solve this problem: • Increase distance to the source of interference. • Turn the device to change the angle of radiation.
  • Page 104: Accessories And Disposables

    12.3 Accessories and disposables  Always use SCHILLER replacement parts and disposables, or products approved by SCHILLER. Failure to do so may endanger life and/or invalidate the warranty. Your local representative stocks all the disposables and accessories available for the CARDIOVIT FT-1.
  • Page 105: 13 Technical Data

    Technical data CARDIOVIT FT-1 User Guide Device 13.1 13 Technical data 13.1 Device Dimensions 230 x 160 x 33 mm, approx. 1.1 kg incl. thermal paper Display • Multi-touch backlit LCD screen for graphic and alphanumeric representation • Resolution: 1200 x 768 dots, 8 “...
  • Page 106 Technical data CARDIOVIT FT-1 13.1 Device Ambient conditions Operating temperature • 10 to 40 °C Relative humidity • 15 to 95% (non-condensing) Pressure during operation • 700 to 1060 hPa Storage temperature • 5 to 50 °C Transport temperature •...
  • Page 107: Ecg

    Technical data CARDIOVIT FT-1 User Guide 13.2 13.2 Patient input Fully floating and isolated, defibrillation protected (only with original SCHILLER pa- tient cable) Lead configurations • Standard 12-lead • Paediatric • Right precordials • Standard C4r • Left posterior • Nehb •...
  • Page 108: Safety Standards

    Technical data CARDIOVIT FT-1 13.3 Safety standards 13.3 Safety standards Safety standard IEC/EN 60601-1 IEC/EN 60601-2-25 IEC/EN 60601-1-2 Protection class Device as a system: Class I in accordance with IEC/EN 60601-1 Conformity/classification CE/IIa in accordance with directive 93/42/EEC Protection This device is not designed for outdoor use (IP 20) 13.4...
  • Page 109: 14 Index

    Index CARDIOVIT FT-1 User Guide 14 Index Accessories and disposables Nehb leads ..........Address Headquarters Network connection ........... Notch filter ........... Baseline filter ........Battery Operation – overview ......Battery life ........Options ..........Capacity ......... Charging time .......
  • Page 110 Index CARDIOVIT FT-1 Page 110...

Table of Contents