Led Indicators; Environmental Monitoring (Optional); Device Reset; Unattended/Automatic Shutdown - CyberPower 1U Series User Manual

Hide thumbs Also See for 1U Series:
Table of Contents

Advertisement

OPERATION

LED Indicators

Indicator
Status
Description
Green
OK
Status
Orange
Warning
Red
Critical
Of
Power Of
On
Power On
(Green)
Tx/Rx
Receiving/transmitting
data packet
Flashing
Reset Finished
Indicates the PDU is connected
On
to the LAN
LINK
Indicates the PDU is not
Of
connected to the LAN
On
Outlet On and providing power
Outlet
Of
Outlet Of

Environmental Monitoring (optional)

CyberPower PDUs along with the environmental sensor
(ENVIROSENSOR) provide temperature and humidity
monitoring in a server closet and/or datacenter remotely.
To connect the PDU with ENVIROSENSOR, use the RJ45
Ethernet Cable included with the ENVIROSENSOR. Plug
one end into the Daisy Chain (In)/ENVIROSENSOR port
on the PDU and the other end into the RJ45 port on
the ENVIROSENSOR (as shown in fgure below). When
the PDU correctly connects to the ENVIROSENSOR,
users can see the temperature and humidity data via
the Web Interface. For further information regarding
ENVIROSENSOR confguration, please refer to the
Intelligent PDU Web Interface User's Manual.

Device Reset

• To locally reset all the settings to default, use Reset
function in the LCD screen.
• To remotely reset all the settings to default, log in to
the Web interface, enter the Reset page and apply the
function.

Unattended/Automatic Shutdown

PowerPanel® Business Edition (Client) software
automatically initiates a graceful shutdown on the
connected computer's operating system. PowerPanel
must be installed on every computer or server for which
the shutdown is to take place. The computer will receive
a message from the PDU, and will perform the shutdown
according to the instructions provided, including shut
downs at exact times and dates.
Step 1. Computer Confguration
1. Install PowerPanel® Business Edition Client on every
computer or server that will be part of the shutdown
process (Follow the instructions in the PowerPanel®
Business Edition User Manual).
2. Confgure the settings in PowerPanel® Business Edition
Client. See the PowerPanel Business® Edition User
Manual for detailed instructions.
Step 2. PDU Confguration
Verify that the IP address of all computers that will be part
of the shutdown process, are included in the Client List on
the web interface.
Step 3. Notifcation
Notifying the computers of potential outlet shutdown can
be accomplished using the following functions:
• Outlets Control Menu: Performing the task of turning of
or rebooting outlets.
• Scheduling Menu: Setting the PDU to perform the task
of turning of or rebooting outlets. The notifcation will
occur prior to the scheduled date/time.
• Outlet Overload: In the event of PDU overload,
notifcation will be sent prior to the PDU shutting down.
27